Sharp VL-A111UL Service Manual - Page 33
Basic iris adjustment
View all Sharp VL-A111UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
6-7-3. CAM circuit adjustment * Before adjusting the CAM circuit, make sure that the fixed value in 6-3-3 is written in E2PROM. VL-A111U/AH131U VL-AH151U/AH161U 6-7-3-1. Supply voltage check Check that the voltages at the following TL are within the specified range (refer to the supply voltage adjustment/check under VCR circuit adjustment). Measuring point Item TL0137 P-CON_4.9V SPEC 4.9V Measuring point Item TL0142 CAM_15V SPEC 15V TL0138 P-CON_3.1V 3.1V TL0143 CAM_-8V -8V TL0140 P-CON_5.7V 5.7V 6-7-3-2. Basic iris adjustment Mode Measuring instrument Subject Measuring point Adjustment address Adjustment reference CAM ADJ - Not specified - 71 09, 0A, 0B DATA 09 0A 0B Description Hole offset adjustment Iris offset adjustment Iris close adjustment 1) Write ADD:70 DATA:01 and enter the lens system adjustment mode. 2) Write DATA "09" in ADD "71" (and confirmed with "PB" the key). * Press the "STOP" key to reconfirm ADD "71". Adjustment is completed when "FF" is returned to DATA. 3) Write ADD "0A" and "0B" in sequence in the same manner. 4) Write ADD:70 DATA:FF and exit the lens system adjustment mode. 6-7-3-3. Lens adjustment Mode CAM ADJ DATA Description Measuring instrument - 12 Optical wide lens adjustment Subject Subject more than 06 Wide lens infinite adjustment 50m away 08 Tele lens infinite adjustment Measuring point - 0D Zoom tracking adjustment Adjustment address 71 Adjustment reference 12, 06, 08, 0D 1) Expose a subject that is more than 50m away. (Nearby subject less than 50m away should not be in the screen.) 2) Write ADD:70 DATA:01 and enter the lens system adjustment mode. 3) Write DATA "12" in ADD "71" (confirmed with "PB" key). * Press the "STOP" key to reconfirm ADD "71". Adjustment is completed when "FF" is returned to DATA. 4) Write ADD "06", "08" and "0D" in sequence in the same manner. 5) Write ADD:70 DATA:FF and exit the lens system adjustment mode. 6-7-3-4. SYNC level adjustment Mode CAM ADJ Measuring instrument Oscilloscope Subject Measuring point Shielded VIDEO OUT 286±10mVp-p(75Ω terminal) Adjustment address 74 Adjustment reference 286±10mVp-p 1) Terminate VIDEO OUT at 75Ω (preferably with resistance lower than 1%). 2) Use a black subject or shield the subject. 3) Write DATA "00" in ADD "70" and enter the camera adjustment mode. 4) Vary ADD "74" data to adjust it to the specification. 5) After confirming the adjustment in step (4), write ADD:70 DATA:FF and exit the camera adjustment mode. 6-7-3-5. SYNC level adjustment Mode CAM ADJ Measuring instrument Oscilloscope 730mVp-p Subject Gray scale Measuring point VIDEO OUT Adjustment address 9C Adjustment reference 730±10mVp-p 1) Terminate VIDEO OUT at 75Ω (preferably with resistance lower than 1%). 2) Record the gray scale (JIGCHART-1). 3) Write DATA "00" in ADD "70" and enter the camera adjustment mode. 4) Vary ADD "9C" data to adjust it to the specification. 5) After confirming the adjustment in step (4), write ADD:70 DATA:FF and exit the camera adjustment mode. 33