Wired Remote Control Terminal Specifications Specifications of wired remote control input • ø3.5 mm minijack • External: GND • Internal: +3.3V Function and transmission codes CONTROL ITEM SYSTEM CODE DATA CODE JUDGEMENT CODE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 ON 1 0 1 1 00 1 1 0 10 1 0 1 0 OFF 1 0 1 1 00 1 1 0 10 0 1 1 0 MENU 1 0 1 1 00 0 1 0 00 1 1 1 0 ∂ 1 0 1 1 00 0 1 1 10 0 1 1 0 ƒ 1 0 1 1 01 0 1 1 10 0 1 1 0 ß 1 0 1 1 00 0 0 0 10 1 0 1 0 © 1 0 1 1 01 1 1 1 00 1 0 1 0 ENTER 1 0 1 1 01 1 1 0 10 1 0 1 0 UNDO 1 0 1 1 01 0 0 1 10 1 0 1 0 THEATER MODE 1 0 1 1 0 1 0 0 1 1 0 0 0 1 0 Wired remote control function code LSB C1 System Code C5 C6 1 0 1 1 0 * * Data Code * * * * MSB C13 C14 C15 * * 1 0 CONTROL ITEM RESIZE GAMMA CLR TEMP + CLR TEMP - AUTO SYNC KEYSTONE INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 SYSTEM CODE DATA CODE JUDGEMENT CODE C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 00 1 1 1 10 1 0 1 0 1 0 1 1 00 0 0 0 00 1 0 1 0 1 0 1 1 01 0 1 1 11 0 0 1 0 1 0 1 1 01 0 0 1 11 1 1 1 0 1 0 1 1 00 1 0 1 11 1 1 1 0 1 0 1 1 01 1 1 1 11 0 1 1 0 1 0 1 1 00 1 0 1 10 0 0 1 0 1 0 1 1 00 1 0 1 11 0 0 1 0 1 0 1 1 01 1 1 0 11 0 0 1 0 1 0 1 1 00 1 0 0 11 0 0 1 0 1 0 1 1 01 0 1 0 11 0 0 1 0 • System codes C1 to C5 are fixed at "10110". • Codes C14 and C15 are reverse confirmation bits, with "10" indicating "Front" and "01" indicating "Rear". Sharp remote control signal format Transmission format: 15-bit format D D D D D D D D D D D D D 67.5 ms 67.5 ms Wave form of output signal: Output using Pulse Position Modulation t T1 T0 "1" "0" "0" "0" 26.4 µs "0" "1" "0" t D • t ‫ ס‬264 µs • T0 ‫ ס‬1.05 ms • T1 ‫ ס‬2.10 ms • Pulse carrier frequency ‫ ס‬37.91 kHz • Duty ratio ‫ ס‬1:1 Transmission control code 15 bit C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 System Address Function Key Data Bit Data Expansion Mask Data Deter- mination Example of Reverse D to D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 1 0 0 0 0 0 0 0 1 0 D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 0 1 1 1 1 1 1 1 0 1 D to D Common Data Bit Reverse in D Appendix E-55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

E-55
Appendix
Wired Remote Control Terminal Specifications
Specifications of wired remote control input
ø
3.5 mm minijack
External: GND
Internal: +3.3V
Function and transmission codes
Wired remote control function code
1
0
1
1
0
*
*
*
*
*
*
*
*
1
0
C1
System Code
C5
C6
Data Code
C13
C14
C15
System codes C1 to C5 are fixed at
10110
.
Codes C14 and C15 are reverse confirmation bits, with
10
indicating
Front
and
01
indicating
Rear
.
LSB
MSB
Sharp remote control signal format
Transmission format:
15-bit format
Wave form of output signal:
Output using Pulse Position Modulation
D
D
D
D
D
D
D
D
D
D
D
D
D
67.5 ms
67.5 ms
“0”
“1”
“0”
D
“0”
“0”
“0”
“1”
T
0
T
1
t
t
26.4
µ
s
t
³
264 µs
T
0
³
1.05 ms
T
1
³
2.10 ms
Transmission control code
15 bit
Pulse carrier frequency
³
37.91 kHz
Duty ratio
³
1:1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
System Address
D to D Common Data Bit
Reverse in D
Function Key Data Bit
Data
Expansion
Data
Deter-
mination
Mask
C15
C1
1
D
C2
0
C3
1
C4
1
C5
0
C6
1
C7
0
C8
0
C9
0
C10
0
C11
0
C12
0
C13
0
C14
1
C15
0
C1
1
D
C2
0
C3
1
C4
1
C5
0
C6
0
C7
1
C8
1
C9
1
C10
1
C11
1
C12
1
C13
1
C14
0
C15
1
CONTROL
ITEM
SYSTEM CODE
C1
1
1
1
1
1
1
1
1
1
1
ON
OFF
MENU
ƒ
ß
©
ENTER
UNDO
THEATER MODE
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
C5
C6
0
0
0
0
1
0
1
1
1
1
1
1
0
0
0
0
1
1
0
0
C7
1
1
1
1
1
0
1
1
0
0
C8
0
0
0
1
1
0
1
0
1
1
C9
1
1
0
1
1
1
0
1
1
1
C10 C11
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
1
1
1
1
0
C12
0
1
1
1
1
0
0
0
0
0
C13
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
C15
DATA CODE
JUDGEMENT
CODE
JUDGEMENT
CODE
CONTROL
ITEM
SYSTEM CODE
C1
1
1
1
1
1
1
1
1
1
1
1
RESIZE
GAMMA
CLR TEMP +
CLR TEMP
AUTO SYNC
KEYSTONE
INPUT 1
INPUT 2
INPUT 3
INPUT 4
INPUT 5
0
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
0
C5
C6
0
0
1
1
0
1
0
0
1
0
1
1
0
0
0
1
1
1
1
1
1
0
C7
1
0
1
0
0
1
0
0
1
0
1
C8
1
0
1
1
1
1
1
1
0
0
0
C9
1
0
1
1
1
1
1
1
1
1
1
C10 C11
0
0
1
1
1
1
0
1
1
1
1
1
1
0
1
1
0
0
0
0
0
0
C12
0
0
0
1
1
1
0
0
0
0
0
C13
1
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
0
C15
DATA CODE
Example of Reverse D to