Sony HDWM2000/20 Operation Manual - Page 123

In 59.94i, 29.97PsF mode, 12H to 18H to 20H, In 50i, 25PsF mode, Item number, Settings

Page 123 highlights

Menu items in the range 600 to 650, relating to the time code generator (Continued) Item number Item name 602 VITC POSITION SEL-2 (Invalid in 24PsF or 23.98PsF mode) Settings In 59.94i, 29.97PsF mode Select a line to insert the VITC in. (For SD output) 12H to 18H to 20H: Select any line from 12 to 20. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 50i, 25PsF mode Select a line to insert the VITC in. (For SD output) 9H to 21H to 22H: Select any line from 9 to 22. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. 603 ID CODE PRESET Select whether or not to set the ID code. OFF : Do not set the ID code. ON: Set the ID code. To set the ID code: Press the F5 (SET) button with this menu item displayed in the menu display, to enter the ID code setting mode. You can then set the user ID digit by digit using the T and t buttons for digit selection. When all required digits have been set correctly, press the F5 (SET) button again to save the ID code and exit from the ID code setting mode. 604 ID CODE SW Select whether or not to record the ID code set using menu item 603 in the user bits. OFF : Record the normal data in the user bits. ON: Record the ID code in the user bits. 605 TCG REGEN MODE Select the signals to be regenerated when the time code generator is in the regeneration mode (i.e., when the function menu item PR/RGN (F2) is set to LTC or VITC, or the unit is in automatic edit mode). TC&UB : Both the time code and user bit signals are regenerated. TC: Only the time code signal is regenerated. UB: Only the user bit signal is regenerated. 606 TC OUTPUT SIGNAL IN Select the signal output from the TIME CODE OUT connector during normal (×1) REGEN MODE speed playback: TAPE : During tape playback, the playback time code signal is output without regeneration. REGEN : The playback time code is output after regeneration. 607 U-BIT BINARY GROUP Select whether to generate time code automatically. FLAG 000 : Character set not specified 001: 8-bit characters compliant with ISO 646 and ISO 2022 010: Undefined 011: Undefined 100: Undefined 101: SMPTE 262M page/line multiplex system 110: Undefined 111: Undefined (Continued) Chapter 10 Setup Menus 10-19 Chapter 10 Setup Menus

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

Chapter 10
Setup Menus
Chapter 10
Setup Menus
10-19
602
VITC POSITION SEL-2
(Invalid in 24PsF or
23.98PsF mode)
In 59.94i, 29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to 18H to 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places.
To insert it in two places, set both
items 601 and 602.
In 50i, 25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to 21H to 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places.
To insert it in two places, set both
items 601 and 602.
Item number
Item name
Settings
603
ID CODE PRESET
Select whether or not to set the ID code.
OFF :
Do not set the ID code.
ON:
Set the ID code.
To set the ID code:
Press the F5 (SET) button with this menu item displayed in the menu display, to
enter the ID code setting mode. You can then set the user ID digit by digit using
the
T
and
t
buttons for digit selection. When all required digits have been set
correctly, press the F5 (SET) button again to save the ID code and exit from the
ID code setting mode.
604
ID CODE SW
Select whether or not to record the ID code set using menu item 603 in the user
bits.
OFF :
Record the normal data in the user bits.
ON:
Record the ID code in the user bits.
605
TCG REGEN MODE
Select the signals to be regenerated when the time code generator is in the
regeneration mode (i.e., when the function menu item PR/RGN (F2) is set to LTC
or VITC, or the unit is in automatic edit mode).
TC&UB :
Both the time code and user bit signals are regenerated.
TC:
Only the time code signal is regenerated.
UB:
Only the user bit signal is regenerated.
606
TC OUTPUT SIGNAL IN
REGEN MODE
Select the signal output from the TIME CODE OUT connector during normal (
×
1)
speed playback:
TAPE :
During tape playback, the playback time code signal is output without
regeneration.
REGEN :
The playback time code is output after regeneration.
607
U-BIT BINARY GROUP
FLAG
Select whether to generate time code automatically.
000 :
Character set not specified
001:
8-bit characters compliant with ISO 646 and ISO 2022
010:
Undefined
011:
Undefined
100:
Undefined
101:
SMPTE 262M page/line multiplex system
110:
Undefined
111:
Undefined
(Continued)