Sony HSCU300RF Operation Manual - Page 8

Rear Panel, CABLE CONDITION indicators

Page 8 highlights

d MENU control block DISP/MENU (display/menu) lever and indicator CANCEL/ENTER lever Control knob • DISP/MENU (display/menu) lever and indicator Selects the status display or setup menu display. In setup menu mode, the indicator turns on. • CANCEL/ENTER lever In setup menu mode, used to cancel and enter settings. • Control knob (rotary encoder) In status screen mode, used to change the displayed page. In setup menu mode, used to move the cursor on a page and to change menu settings. Pressing the control knob performs the same function as setting the CANCEL/ENTER lever to the ENTER position. e POWER switch Switches the power for the entire system on and off, including the CCU, camera, and the RCP-1000-series Remote Control Panel connected to the REMOTE connector on the rear panel. Pressing the "?" side turns the camera system on, and pressing the "a" side turns it off. f POWER indicator CAM: Turns on when power is supplied to the camera. MAIN: Turns on when the CCU power supply is turned on. It flashes when there is a problem with the fan. g NETWORK indicator Displays the network system connection status. On: Indicates that external control equipment (MSU-1000/1500 Master Setup Unit, RCP-1000-series Remote Control Panel, or other device) is connected. Flashing: Indicates a connection problem with the external control equipment (MSU-1000/1500 Master Setup Unit, RCP-1000-series Remote Control Panel, or other device). Off: Indicates that a LAN cable is not connected or that the network system connection parameters have not been set. See "Network diagnostics" on page 14 and "NETWORK SETTINGS menu" on page 28. h CABLE CONDITION indicators Indicates the communication status of the camera (CAM) and camera control unit (CCU). When the two lamps on the right (green) are lighted: Reception status is excellent. When the second lamp from the right (green) is lighted: Reception status is good. When the second lamp from the left (yellow) is lighted: Reception status is low. When the lamp on the left (red) is lighted: Reception status is at the lowest level. • On the HSCU300RF, determined by the receive level of the optical signal on the camera and CCU. • On the HSCU300R, determined by the receive level of the RF signal on the CCU. Rear Panel a b c d ef g h i j k Memory stick slot (for use by service personnel only) l m no p HSCU300RF diagram shown. a REFERENCE IN/OUT (reference input) connectors (BNC type) Inputs an HD tri-level reference sync signal or SD reference sync signal (black burst signal) on either of the two connectors. The input signal is output from the other connector as-is (loopthrough output). The signal is input on the upper connector. The lower connector is terminated automatically if no connector is connected. b PROMPTER 1, 2 (teleprompter input 1, 2) connectors (BNC type) Inputs the VBS signals for the teleprompter. Note On the HSCU300RF, only one system from the two systems on the PROMPTER1 and 2 connectors is enabled. c VBS RETURN 1, 2 (VBS return video 1, 2 input) connectors (BNC type) Inputs the 2-system VBS return video signals. 8 Locations and Functions of Parts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

8
Locations and Functions of Parts
d
MENU control block
DISP/MENU (display/menu) lever and indicator
Selects the status display or setup menu display. In setup
menu mode, the indicator turns on.
CANCEL/ENTER lever
In setup menu mode, used to cancel and enter settings.
Control knob (rotary encoder)
In status screen mode, used to change the displayed page. In
setup menu mode, used to move the cursor on a page and to
change menu settings.
Pressing the control knob performs the same function as
setting the CANCEL/ENTER lever to the ENTER position.
e
POWER switch
Switches the power for the entire system on and off, including
the CCU, camera, and the RCP-1000-series Remote Control
Panel connected to the REMOTE connector on the rear panel.
Pressing the “
?
” side turns the camera system on, and
pressing the “
a
” side turns it off.
f
POWER indicator
CAM:
Turns on when power is supplied to the camera.
MAIN
: Turns on when the CCU power supply is turned on. It
flashes when there is a problem with the fan.
g
NETWORK indicator
Displays the network system connection status.
On
: Indicates that external control equipment
(MSU-1000/1500 Master Setup Unit, RCP-1000-series
Remote Control Panel, or other device) is connected.
Flashing
: Indicates a connection problem with the external
control equipment (MSU-1000/1500 Master Setup Unit,
RCP-1000-series Remote Control Panel, or other device).
Off
: Indicates that a LAN cable is not connected or that the
network system connection parameters have not been set.
See “Network diagnostics” on page 14 and “NETWORK
SETTINGS menu” on page 28.
h
CABLE CONDITION indicators
Indicates the communication status of the camera (CAM) and
camera control unit (CCU).
When the two lamps on the right (green) are lighted:
Reception status is excellent.
When the second lamp from the right (green) is lighted:
Reception status is good.
When the second lamp from the left (yellow) is lighted:
Reception status is low.
When the lamp on the left (red) is lighted:
Reception status
is at the lowest level.
On the HSCU300RF, determined by the receive level of the
optical signal on the camera and CCU.
On the HSCU300R, determined by the receive level of the
RF signal on the CCU.
Rear Panel
a
REFERENCE IN/OUT (reference input) connectors
(BNC type)
Inputs an HD tri-level reference sync signal or SD reference
sync signal (black burst signal) on either of the two connectors.
The input signal is output from the other connector as-is (loop-
through output). The signal is input on the upper connector.
The lower connector is terminated automatically if no
connector is connected.
b
PROMPTER 1, 2 (teleprompter input 1, 2) connectors
(BNC type)
Inputs the VBS signals for the teleprompter.
On the HSCU300RF, only one system from the two systems on the
PROMPTER1 and 2 connectors is enabled.
c
VBS RETURN 1, 2 (VBS return video 1, 2 input)
connectors (BNC type)
Inputs the 2-system VBS return video signals.
DISP/MENU (display/menu) lever and indicator
CANCEL/ENTER lever
Control knob
abc
l
o
m
n
p
d
g
f
h
e
i
j
k
Memory stick slot (for use
by service personnel only)
HSCU300RF diagram shown.
Note