Sony HSCU300RF Operation Manual - Page 9

Pr/R/R-Y, Y/G/Y, Pb/B/B-Y component signals, MIC/WF REMOTE/TRUNK microphone/waveform

Page 9 highlights

d Pr/R/R-Y, Y/G/Y, Pb/B/B-Y (component signals) connectors (BNC type) Outputs the HD component signals, SD component signals, HD RGB signals, or SD RGB signals from the corresponding connectors. e PIX (picture monitor output) connector (BNC type) Outputs a video signal for a picture monitor. It can also output a signal with superimposed character display. f SYNC/WF (sync signal output/waveform monitor output) connector (BNC type) Outputs a sync signal or video signal for a waveform monitor. g REMOTE connector (8-pin) Transmits and receives control signals from a MSU-1000/1500 Master Setup Unit, CNU-700 Camera Command Network Unit, or RCP-1000-series Remote Control Panel via a CCA-5 cable (optional). It also supplies power when connected to an RCP-1000-series Remote Control Panel. h INTERCOM/TALLY/PGM (intercom/tally/program audio) connector (D-sub 25-pin) Transmits and receives the various intercom, tally, and program audio signals. It connects to the intercom/tally/program audio connector of the intercom system. i MIC OUT1, MIC OUT2 (microphone output 1, 2) connectors (XLR 3-pin) Outputs the camera microphone signals. j CAMERA connector (optical fiber connector/triax connector) Connects to the camera via an optical fiber cable or a triax cable. The camera sends all video and audio signals to the CCU, and the CCU sends control signals, return video and audio signals, as well as power, to the camera over a single optical fiber cable or triax cable. k AC supply input connector Connects to the AC supply via the specified power cord (optional). A plug holder (optional) can be used to secure the power cord to the CCU. l SDI RETURN 1, 2 (SDI return video 1, 2 input) connectors (BNC type) Inputs the HD SDI return video signals or SD SDI return video signals (2-system). Can also be configured as the HD/SD SDI Prompter input connector. Note The HSCU300RF does not support SDI Prompter. m SDI OUTPUT 1 to 4 connectors (BNC type) Outputs the camera signals in HD SDI or SD SDI signal format. The SDI OUTPUT 3 and SDI OUTPUT 4 connectors can also output signals with superimposed character or marker display. n VBS 1, 2 (composite video signal 1, 2) connectors (BNC type) Outputs (2-system) the camera signals in composite signal format. o (LAN) jack (RJ-45, 8-pin) Connects to a LAN hub (10BASE-T/100BASE-TX), when using a network connection, via a LAN cable (shielded type, category 5 or higher). p MIC/WF REMOTE/TRUNK (microphone/waveform monitor remote/trunk) connector (D-sub 25-pin) Supports the following functions. • Microphone remote Connects to an external control device, such as an audio mixer, which can select the camera microphone gain to one of five values (20/30/40/50/60 dB) in response to the audio conditions when shooting. This connector can also output a red tally signal and green tally signal. • Waveform monitor remote Connects to corresponding connector on a recall-type waveform monitor. Outputs a signal used for remote control of the waveform monitor display by an MSU-1000/1500 Master Setup Unit or RCP-1000 series Remote Control Panel. For connection details, refer to the waveform monitor manual. • Waveform monitor mode output Connects to a waveform monitor and is used when monitoring each of the 3 R/G/B waveforms simultaneously in sequential mode. When the SEQ button on the MSU-1000/1500 Master Setup Unit or RCP-1000-series Remote Control Panel is pressed, the video signal output from the WF connector changes to a sequence signal. • Trunk Connects to an external device to provide a communication path between it and the external device connected to the REMOTE connector on the camera. 9 Locations and Functions of Parts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

9
Locations and Functions of Parts
d
Pr/R/R-Y, Y/G/Y, Pb/B/B-Y (component signals)
connectors (BNC type)
Outputs the HD component signals, SD component signals,
HD RGB signals, or SD RGB signals from the corresponding
connectors.
e
PIX (picture monitor output) connector (BNC type)
Outputs a video signal for a picture monitor. It can also output
a signal with superimposed character display.
f
SYNC/WF (sync signal output/waveform monitor
output) connector (BNC type)
Outputs a sync signal or video signal for a waveform monitor.
g
REMOTE connector (8-pin)
Transmits and receives control signals from a MSU-1000/1500
Master Setup Unit, CNU-700 Camera Command Network
Unit, or RCP-1000-series Remote Control Panel via a CCA-5
cable (optional). It also supplies power when connected to an
RCP-1000-series Remote Control Panel.
h
INTERCOM/TALLY/PGM (intercom/tally/program
audio) connector (D-sub 25-pin)
Transmits and receives the various intercom, tally, and
program audio signals. It connects to the
intercom/tally/program audio connector of the intercom
system.
i
MIC OUT1, MIC OUT2 (microphone output 1, 2)
connectors (XLR 3-pin)
Outputs the camera microphone signals.
j
CAMERA connector (optical fiber connector/triax
connector)
Connects to the camera via an optical fiber cable or a triax
cable. The camera sends all video and audio signals to the
CCU, and the CCU sends control signals, return video and
audio signals, as well as power, to the camera over a single
optical fiber cable or triax cable.
k
AC supply input connector
Connects to the AC supply via the specified power cord
(optional). A plug holder (optional) can be used to secure the
power cord to the CCU.
l
SDI RETURN 1, 2 (SDI return video 1, 2 input)
connectors (BNC type)
Inputs the HD SDI return video signals or SD SDI return video
signals (2-system).
Can also be configured as the HD/SD SDI Prompter input
connector.
The HSCU300RF does not support SDI Prompter.
m
SDI OUTPUT 1 to 4 connectors (BNC type)
Outputs the camera signals in HD SDI or SD SDI signal
format.
The SDI OUTPUT 3 and SDI OUTPUT 4 connectors can also
output signals with superimposed character or marker display.
n
VBS 1, 2 (composite video signal 1, 2) connectors
(BNC type)
Outputs (2-system) the camera signals in composite signal
format.
o
(LAN) jack (RJ-45, 8-pin)
Connects to a LAN hub (10BASE-T/100BASE-TX), when
using a network connection, via a LAN cable (shielded type,
category 5 or higher).
p
MIC/WF REMOTE/TRUNK (microphone/waveform
monitor remote/trunk) connector (D-sub 25-pin)
Supports the following functions.
Microphone remote
Connects to an external control device, such as an audio
mixer, which can select the camera microphone gain to one of
five values (20/30/40/50/60 dB) in response to the audio
conditions when shooting.
This connector can also output a red tally signal and green
tally signal.
Waveform monitor remote
Connects to corresponding connector on a recall-type
waveform monitor.
Outputs a signal used for remote control of the waveform
monitor display by an MSU-1000/1500 Master Setup Unit or
RCP-1000 series Remote Control Panel.
For connection details, refer to the waveform monitor manual.
Waveform monitor mode output
Connects to a waveform monitor and is used when monitoring
each of the 3 R/G/B waveforms simultaneously in sequential
mode.
When the SEQ button on the MSU-1000/1500 Master Setup
Unit or RCP-1000-series Remote Control Panel is pressed,
the video signal output from the WF connector changes to a
sequence signal.
• Trunk
Connects to an external device to provide a communication
path between it and the external device connected to the
REMOTE connector on the camera.
Note