Sony MZ-R900 Operating Instructions - Page 17

Record an MD

Page 17 highlights

2 Record an MD END SEARCH REC x 1 Press and slide REC to the right. " REC" lights up and recording starts. 2 Play the CD or tape you want to record. To stop recording, press x. After you press x, the recorder will automatically turn off in about 10 seconds (when using batteries) or about 5 minutes (when using AC power adaptor). To Record from the end of the previous recording1) Record partway through the previous recording1) Pause Remove the MD Press END SEARCH, and then press and slide REC to the right. Press jog lever (R) (N), or flip the jog lever (R) towards > or . to find the start point of recording and press x to stop. Then press and slide REC to the right. X2) Press X again to resume recording. x and open the lid.3) (The lid does not open while " TOC Edit" flashing in the display.) 1) By setting " REC-Posi" to " From End" , recording operations will always start from the end of the previously recorded material (page 25). 2) A track mark is added at the point where you press X again to resume recording while pausing; thus the remainder of the track will be counted as a new track. 3) If you open the lid while " REC-Posi" is set to " From Here" , recording will begin with the first track the next time you record. Check the point to start recording on the display. If the recording does not start • Make sure the recorder is not locked (page 55). • Make sure the MD is not record-protected (page 59). • Premastered MDs cannot be recorded over. For models supplied with the AC plug adaptor If the AC power adaptor does not fit the wall outlet, use the AC plug adaptor. Notes • " Data Save" or " TOC Edit" flashes while data of the recording (the track's start and end points, etc.) is being recorded. Do not move or jog the recorder or disconnect the power source while the indication is flashing in the display. • The lid does not open until " TOC Edit" disappears in the display. • If the power supply is disrupted (i.e. the battery is removed or becomes exhausted or the AC power adaptor is disconnected) during a recording or editing operation, or while " TOC Edit" appears in the display, then it will not be possible to open the lid until power is restored. 17-GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

17
-GB
2
Record an MD
1
Press and slide REC to the right.
“ REC” lights up and recording starts.
2
Play the CD or tape you want to record.
To stop recording, press
x
.
After you press
x
, the recorder will
automatically turn off in about 10 seconds
(when using batteries) or about 5 minutes
(when using AC power adaptor).
If the recording does not start
Make sure the recorder is not locked
(page 55).
Make sure the MD is not record-protected
(page 59).
Premastered MDs cannot be recorded over.
For models supplied with the AC plug
adaptor
If the AC power adaptor does not fit the wall
outlet, use the AC plug adaptor.
Notes
“ Data Save” or “ TOC Edit” flashes while data
of the recording (the track’s start and end
points, etc.) is being recorded. Do not move or
jog the recorder or disconnect the power
source while the indication is flashing in the
display.
The lid does not open until “ TOC Edit”
disappears in the display.
If the power supply is disrupted (i.e. the
battery is removed or becomes exhausted or
the AC power adaptor is disconnected) during
a recording or editing operation, or while
“ TOC Edit” appears in the display, then it will
not be possible to open the lid until power is
restored.
END SEARCH
REC
x
To
Press
Record from the end of the previous
recording
1)
END SEARCH, and then press and slide
REC to the right.
Record partway through the previous
recording
1)
Press jog lever (R) (
N
), or flip the jog
lever (R) towards
>
or
.
to find the
start point of recording and press
x
to stop.
Then press and slide REC to the right.
Pause
X
2)
Press
X
again to resume recording.
Remove the MD
x
and open the lid.
3)
(The lid does not open
while “ TOC Edit” flashing in the display.)
1)
By setting “ REC-Posi” to “ From End” , recording operations will always start from the end of the
previously recorded material (page 25).
2)
A track mark is added at the point where you press
X
again to resume recording while pausing; thus
the remainder of the track will be counted as a new track.
3)
If you open the lid while “ REC-Posi” is set to “ From Here” , recording will begin with the first track
the next time you record. Check the point to start recording on the display.