MZ-R900 SECTION 4 TEST MODE Outline • This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be automatically adjusted. • Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key. • For the LCD display, the LCD on the remote commander is shown, but the contents of LCD display on the set are same. Operation in Setting the Test Mode • When the test mode becomes active, first the display check mode is selected. • Other mode can be selected from the display check mode. • When the test mode is set, the LCD repeats the following dis- play. Remote commander LCD display All lit 888 BASS12 Setting Method of Test Mode There are two different methods to set the test mode: 1 Short SL801 (TEST) on the MAIN board with a solder bridge (connect pin 3 of IC801 to the ground). Then, turn on the power. All off - MAIN Board (Conductor Side) - Microcomputer version 003 V1.000 display Destination code 002 : Except US, Canadian models 003 : US, Canadian models 3 79 77 70 81 60 58 0 74 67 65 63 62 57 61 31 133 135 137 68 55 54 56 4 76 73 66 59 49 53 44 50 47 35 36 45 31 30 51 113 24 42 IC801 25 20 26 28 16 40 23 17 38 21 15 34 27 8 22 96 95 18 19 4 9 29 2 7 613 48 10 5 241 12 11 C801 C813 + C809 + C830 L801 SL801 (TEST) • When the X key is pressed and hold down, the display at that time is held so that display can be checked. Caution: On the set having the microcomputer version 1.000, some adjusted values were set in the manual mode at the shipment, but these data will be cleared when the NV is reset. Therefore, on the set having the microcomputer version 1.000, change the adjusted values following the Change of Adjusted Values immediately after the NV was reset (see page 17). Releasing the Test Mode For test mode set with the method 1: Turn off the power and open the solder bridge on SL801 (TEST) on the MAIN board. Note: Remove the solders completely. Remaining could be shorted with the chassis, etc. For test mode set with the method 2: Turn off the power. Note: If electrical adjustment (see page 17) has not been finished com- pletely, always start in the test mode. (The set cannot start in normal mode) 2 In the normal mode, turn on the [HOLD] switch. While pressing the [VOL --] key press the following order: >t>t.t.t>t . t> t . t X t X 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

12
MZ-R900
888
003
V1.000
Microcomputer
version
display
Destination code
002 : Except US, Canadian models
003 : US, Canadian models
All off
All lit
BASS12
C830
+
L801
C809
+
C813
C801
11
12
241
5
10
48
3
1
6
7
2
29
9
4
19
18
95
96
22
8
27
34
15
21
38
17
23
40
16
28
26
20
25
42
24
113
51
30
31
45
36
35
47
50
44
53
49
59
56
54
55
61
57
62
58
60
68
63
81
137
65
70
135
67
77
133
74
79
31
66
73
76
4
0
3
IC801
SL801
(TEST)
– MAIN Board (Conductor Side) –
2
In the normal mode, turn on the
[HOLD]
switch. While press-
ing the
[VOL°--]
key press the following order:
>
t
>
t
.
t
.
t
>
t
.
t
>
t
.
t
X
t
X
SECTION
4
TEST
MODE
Operation in Setting the Test Mode
When the test mode becomes active, first the display check mode
is selected.
Other mode can be selected from the display check mode.
When the test mode is set, the LCD repeats the following dis-
play.
Remote commander LCD display
When the
X
key is pressed and hold down, the display at that
time is held so that display can be checked.
Caution:
On the set having the microcomputer version 1.000,
some adjusted values were set in the manual mode at
the shipment, but these data will be cleared when the
NV is reset. Therefore, on the set having the micro-
computer version 1.000, change the adjusted values
following the Change of Adjusted Values immediately
after the NV was reset (see page 17).
Releasing the Test Mode
For test mode set with the method
1
:
Turn off the power and open the solder bridge on SL801 (TEST)
on the MAIN board.
Note:
Remove the solders completely. Remaining could be shorted with
the chassis, etc.
For test mode set with the method
2
:
Turn off the power.
Note:
If electrical adjustment (see page 17) has not been finished com-
pletely, always start in the test mode. (The set cannot start in nor-
mal mode)
Outline
This set provides the Overall adjustment mode that allows CD
and MO discs to be automatically adjusted when in the test mode.
In this overall adjustment mode, the disc is discriminate between
CD and MO, and each adjustment is automatically executed in
order.
If a fault is found, the system displays its location.
Also,
the manual mode allows each individual adjustment to be auto-
matically adjusted.
Operation in the test mode is performed with the set. A key
having no particular description in the text, indicates a set key.
For the LCD display, the LCD on the remote commander is
shown, but the contents of LCD display on the set are same.
Setting Method of Test Mode
There are two different methods to set the test mode:
1
Short SL801 (TEST) on the MAIN board with a solder bridge
(connect pin
3
of IC801 to the ground).
Then, turn on the
power.