Sony VPL VW10HT Operating Instructions - Page 37

Others, Warning messages, Caution messages - resolution

Page 37 highlights

Troubleshooting Others Symptom The LAMP/COVER indicator flashes. The LAMP/COVER indicator lights up. Cause The lamp cover or the air filter cover is detached. The lamp has reached the end of its life. The lamp becomes a high temperature. The TEMP/FAN indicator flashes. The fan is broken. The TEMP/FAN indicator lights up. The internal temperature is unusually high. Both LAMP/COVER and The electric system failed. TEMP/FAN indicators light up. Remedy Attach the cover securely (see pages 34 (GB) and 35 (GB)). Replace the lamp (see page 34 (GB)). Wait for 120 seconds to cool down the lamp and turn on the power again (see page 20 (GB)). Consult with qualified Sony personnel. Check to see if nothing is blocking the ventilation holes. Consult with qualified Sony personnel. Warning messages Use the list below to check the meaning of the messages displayed on the screen. Message High temp.! Lamp off in 1 min. Frequency is out of range! Please check INPUT-A setting. Please check INPUT-B setting. Please replace the LAMP. Meaning Remedy Internal temperature is too high. This input signal cannot be projected as the frequency is out of the acceptable range of the projector. The resolution setting of the output signal of a computer is too high. Turn off the power. Check to see if nothing is blocking the ventilation holes. Input a signal that is within the range of the frequency. Set the setting of output to the XGA (see page 16 (GB)). You have input RGB signal from the computer when INPUT-A in the SET SETTING menu is set to COMPONENT, DTV YPBPR or DTV GBR. You have input RGB signal from the computer when INPUT-B in the SET SETTING menu is set to COMPONENT, DTV YPBPR or DTV GBR. It is time to replace the lamp. Set INPUT-A correctly (see page 27 (GB)). Set INPUT-B correctly (see page 27 (GB)). Please replace the lamp. Caution messages Use the list below to check the meaning of the messages displayed on the screen. Message NO INPUT Not applicable! Meaning No input signal You have pressed the wrong key. Remedy Check connections (see page 15 (GB) and 16 (GB)). Press the appropriate key. 37 (GB)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

37
(GB)
Troubleshooting
Others
Symptom
Cause
Remedy
The LAMP/COVER indicator
flashes.
The lamp cover or the air filter cover is
detached.
Attach the cover securely
(see pages 34 (GB) and
35 (GB)).
The LAMP/COVER indicator
lights up.
The lamp has reached the end of its life.
Replace the lamp
(see page 34 (GB)).
The lamp becomes a high temperature.
Wait for 120 seconds to cool down the lamp and
turn on the power again
(see page 20 (GB))
.
The TEMP/FAN indicator
flashes.
The fan is broken.
Consult with qualified Sony personnel.
The TEMP/FAN indicator
lights up.
The internal temperature is unusually
high.
Check to see if nothing is blocking the ventilation
holes.
Warning messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Caution messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Meaning
Remedy
High temp.!
Lamp off in 1 min.
Internal temperature is too high.
Turn off the power.
Check to see if nothing is blocking the ventilation
holes.
Frequency is out of range!
This input signal cannot be projected as
the frequency is out of the acceptable
range of the projector.
Input a signal that is within the range of the
frequency.
The resolution setting of the output
signal of a computer is too high.
Set the setting of output to the XGA
(see page 16
(GB)).
NO INPUT
No input signal
Check connections
(see page 15 (GB) and 16 (GB))
.
Not applicable!
You have pressed the wrong key.
Press the appropriate key.
Please check INPUT-A
setting.
You have input RGB signal from the
computer when INPUT-A in the SET
SETTING menu is set to COMPONENT,
DTV YP
B
P
R
or DTV GBR.
Set INPUT-A correctly
(see page 27 (GB))
.
Meaning
Remedy
Please check INPUT-B
setting.
You have input RGB signal from the
computer when INPUT-B in the SET
SETTING menu is set to COMPONENT,
DTV YP
B
P
R
or DTV GBR.
Set INPUT-B correctly
(see page 27 (GB))
.
Both LAMP/COVER and
TEMP/FAN indicators light up.
The electric system failed.
Consult with qualified Sony personnel.
Please replace the LAMP.
It is time to replace the lamp.
Please replace the lamp.