22 Troubleshooting Guide 22 Troubleshooting Guide English 22.1 Troubleshooting Always remove the activation key before carrying out any inspection, cleaning or maintenance. Condition LEDs on the blower 3 LEDs flash red. Blower does not start when switched on. 1 LED flashes green. 3 LEDs glow red. Blower cuts out during operation. 3 LEDs glow red. Run-time is too short. Cause Remedy Malfunction in blower. ► Do not attempt to use. The blower has a malfunction and must be checked by a servicing dealer. Activation key not fully inserted. ► Remove the activation key, @ 13.2. ► Visually check the electrical contacts of the activation key. ► Reinsert the activation key, @ 13.1. Less than 20 % ► Charge the blower, @ 10. charge remaining. Integrated battery too hot. ► Remove the activation key, @ 13.2. ► Allow the blower to cool down gradually at ambient temperatures of about 50 °F to 68 °F (10 °C to 20 °C). Moisture in blower. ► Allow the blower to dry. Integrated battery too hot. ► Remove the activation key, @ 13.2. ► Allow the blower to cool down gradually at ambient temperatures of about 50 °F to 68 °F (10 °C to 20 °C). Electrical malfunction. ► Switch off the blower. Wait at least 5 seconds and switch it back on, @ 14. Blower not fully charged. ► Charge the blower, @ 10. Useful life of ► Have the blower checked by an authorized STIHL servicing integrated battery dealer. has been reached or exceeded. Integrated battery too hot / too cold. ► Allow the blower to warm up or cool down gradually at ambient temperatures of about 50 °F to 68 °F (10 °C to 20 °C). Blower is not being 3 LEDs glow charged. red. Integrated battery too hot / too cold. ► Allow the blower to warm up or cool down gradually at ambient temperatures of about 50 °F to 68 °F (10 °C to 20 °C). ► Operate the charger only in enclosed, dry rooms at ambient temperatures of 32 °F to 104 °F (0 °C to 40 °C). 0458-719-8621-A 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

0458-719-8621-A
23
English
22 Troubleshooting Guide
22.1
Troubleshooting
22
Troubleshooting Guide
Always remove the activation key before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on the
blower
Cause
Remedy
3 LEDs flash
red.
Malfunction in
blower.
Do not attempt to use. The blower has a malfunction and
must be checked by a servicing dealer.
Blower does not start
when switched on.
Activation key not
fully inserted.
Remove the activation key,
@
13.2.
Visually check the electrical contacts of the activation key.
Reinsert the activation key,
@
13.1.
1 LED flashes
green.
Less than 20 %
charge remaining.
Charge the blower,
@
10.
3 LEDs glow
red.
Integrated battery
too hot.
Remove the activation key,
@
13.2.
Allow the blower to cool down gradually at ambient
temperatures of about 50 °F to 68 °F (10 °C to 20 °C).
Moisture in blower.
Allow the blower to dry.
Blower cuts out
during operation.
3 LEDs glow
red.
Integrated battery
too hot.
Remove the activation key,
@
13.2.
Allow the blower to cool down gradually at ambient
temperatures of about 50 °F to 68 °F (10 °C to 20 °C).
Electrical
malfunction.
Switch off the blower. Wait at least 5 seconds and switch it
back on,
@
14.
Run-time is too short.
Blower not fully
charged.
Charge the blower,
@
10.
Useful life of
integrated battery
has been reached or
exceeded.
Have the blower checked by an authorized STIHL servicing
dealer.
Integrated battery
too hot / too cold.
Allow the blower to warm up or cool down gradually at
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Blower is not being
charged.
3 LEDs glow
red.
Integrated battery
too hot / too cold.
Allow the blower to warm up or cool down gradually at
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Operate the charger only in enclosed, dry rooms at ambient
temperatures of 32 °F to 104 °F (0 °C to 40 °C).