Sub-Zero 427 Wine Storage Installation Instructions - Page 18
Models 427G and 427RG Installation, Electrical Requirements - 427rg 2
View all Sub-Zero 427 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Models 427G and 427RG Installation 18 Electrical Requirements For models 427G and 427RG, the electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: For models 427G and 427RG, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded. Do not use an extension cord or two-prong adapter. Do not remove the power supply cord ground prong. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type LEFT SIDE OF OPENING 21/2" (64) 13" (330) 41/2" (114) 1/4" FLOOR (6) FRONT VIEW Location of electrical supply.