Models 424G and 424FSG Installation, Electrical Requirements
View all Sub-Zero 427 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Models 424G and 424FSG Installation 6 Electrical Requirements For models 424G and 424FSG, the electrical supply should be located within the shaded area shown in the illustration. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: For model 424G, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity and is properly grounded. Do not use an extension cord or two-prong adapter. Electrical ground is required on this appliance. Do not remove the power cord ground prong. Electrical Requirements Power Supply Circuit Breaker Receptacle LEFT SIDE OF OPENING 2" (51) 151/2" (394) 3" (76) FRONT VIEW Location of electrical supply. 115 V AC, 60 Hz 15 amp 3-prong grounding-type