Sub-Zero 427R Sub-Zero Design Guide - Page 23

Flush Inset Installation

Page 23 highlights

Built-In Refrigeration 23 subzero.com/specs Built-In Models FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET DEPTH 23/16" (56) TOP VIEW 11/4" (32) UNIT WITH 3/4" (19) PANEL CLEAT DETAIL A 83 3/4" (2127) HEIGHT TO CLEAT 84" (2134) FLUSH INSET HEIGHT 11/4" (32) A WIDTH TO CLEAT B FLUSH INSET WIDTH 11/4" (32) 26 3/16" 24" (610) (665) OPENING FLUSH DEPTH INSET TO CLEAT DEPTH 23/16" (56) Detail A TOP VIEW CLEAT 3" (76) typical 11/4" (32) CLEAT 3" typical (76) 4" (102) SHADED AREA MUST BE FINISHED 24" (610) OPENING DEPTH TO CLEAT 23/16" (56) Detail B 11/4" (32) DETAIL B SIDE VIEW Flush Inset Opening Widths BI-36R, BI-36RG and BI-36F BI-30U and BI-30UG BI-36U and BI-36UG BI-36S BI-42S, BI-42SID and BI-42SD BI-48S, BI-48SID and BI-48SD FRONT VIEW A 351/2" (902) 291/2" (746) 351/2" (902) 351/2" (902) 411/2" (1054) 471/2" (1206) B 38" (965) 32" (813) 38" (965) 38" (965) 44" (1118) 50" (1270) Dimensions assume a 3/4" (19) panel thickness. IMPORTANT NOTE: If an 83" (2108) grille height is specified, the height to cleat and flush inset height must be decreased by 7/8" (22). If an 88" (2235) grille height is specified, the height to cleat and flush inset height increases by 4" (102). If two units are installed side by side, refer to pages 32-36 for dual flush inset installations.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Built-In Refrigeration
23
subzero.com/specs
Flush Inset Opening Widths
A
B
BI-36R, BI-36RG and BI-36F
35
1
/
2
"
(902)
38"
(965)
BI-30U and BI-30UG
29
1
/
2
"
(746)
32"
(813)
BI-36U and BI-36UG
35
1
/
2
"
(902)
38"
(965)
BI-36S
35
1
/
2
"
(902)
38"
(965)
BI-42S, BI-42SID and BI-42SD
41
1
/
2
"
(1054)
44"
(1118)
BI-48S, BI-48SID and BI-48SD
47
1
/
2
"
(1206)
50"
(1270)
UNIT WITH
3
/
4
"
(19)
PANEL
DETAIL A
DETAIL B
FRONT VIEW
A
WIDTH TO CLEAT
B
FLUSH INSET WIDTH
1
1
/
4
"
(32)
1
1
/
4
"
(32)
SIDE VIEW
84"
(2134)
FLUSH
INSET
HEIGHT
1
/
4
"
(6)
24"
(610)
DEPTH TO CLEAT
26
3
/
16
"
(665)
FLUSH INSET DEPTH
2
3
/
16
"
(56)
83
3
/
4
"
(2127)
HEIGHT
TO CLEAT
24"
(610)
DEPTH
TO CLEAT
26
3
/
16
"
(665)
FLUSH
INSET
DEPTH
TOP VIEW
2
3
/
16
"
(56)
1
1
/
4
"
(32)
CLEAT
CLEAT
Detail A
Detail B
1
1
/
4
"
(32)
24"
(610)
OPENING
DEPTH
TO CLEAT
CLEAT
TOP VIEW
26
3
/
16
"
(665)
FLUSH
INSET
DEPTH
2
3
/
16
"
(56)
3"
(76)
typical
24"
(610)
OPENING
DEPTH TO
CLEAT
1
1
/
4
"
(32)
2
3
/
16
"
(56)
CLEAT
SHADED
AREA
MUST BE
FINISHED
3"
typical
(76)
4"
(102)
Built-In Models
FLUSH INSET INSTALLATION
Dimensions assume a
3
/
4
"
(19)
panel thickness.
IMPORTANT NOTE:
If an 83"
(2108)
grille height is specified,
the height to cleat and flush inset height must be decreased
by
7
/
8
"
(22)
. If an 88"
(2235)
grille height is specified, the height
to cleat and flush inset height increases by 4"
(102)
.
If two units are installed side by side, refer to pages 32–36 for
dual flush inset installations.