Sub-Zero 427R Sub-Zero Design Guide - Page 56

Integrated Refrigeration, Electrical Requirements

Page 56 highlights

Integrated Refrigeration 56 Electrical Requirements The electrical supply should be located within the shaded area shown in the illustrations. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance, is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type LEFT SIDE OF OPENING LEFT SIDE OF OPENING 21/2" (64) 13" (330) 41/2" (114) 1/4" FLOOR (6) FRONT VIEW 21/2" (64) 171/2" (445) 1/4" FLOOR (6) FRONT VIEW 41/2" (114) 27" (686) models. 36" (914) models.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Integrated Refrigeration
56
Electrical Requirements
The electrical supply should be located within the shaded
area shown in the illustrations. Follow the National
Electrical Code and local codes and ordinances when
installing the receptacle. A separate circuit, servicing only
this appliance, is required. A ground fault circuit inter-
rupter (GFCI) is not recommended and may cause inter-
ruption of operation.
IMPORTANT NOTE:
It is critical that the electrical outlet be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket. It must be
flush with the back wall and positioned with the grounding
prong to the right of the thinner blades.
Electrical Requirements
Power Supply
115 V AC, 60 Hz
Circuit Breaker
15 amp
Receptacle
3-prong grounding-type
13"
(330)
1
/
4
"
(6)
4
1
/
2
"
(114)
LEFT SIDE
OF OPENING
FLOOR
2
1
/
2
"
(64)
FRONT VIEW
27" (686) models.
36" (914) models.
17
1
/
2
"
(445)
4
1
/
2
"
(114)
FRONT VIEW
FLOOR
1
/
4
"
(6)
LEFT SIDE
OF OPENING
2
1
/
2
"
(64)