Sub-Zero 427R Sub-Zero Design Guide - Page 57

Integrated Refrigeration, Plumbing Requirements

Page 57 highlights

Integrated Refrigeration 57 subzero.com/specs Plumbing Requirements For integrated models with an automatic ice maker, the water supply line should be located through the floor or back wall, within the shaded area shown in the illustrations. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. Do not use self-piercing valves. A saddle valve kit is available through your authorized Sub-Zero dealer. IMPORTANT NOTE: It is critical that the water line be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. IMPORTANT NOTE: A reverse osmosis system can be used provided there is constant water pressure of 20 psi (1.4 bar) to 100 psi (6.9 bar) supplied to the unit at all times. In some cases, a reverse osmosis water filter system may not be able to maintain the minimum pressure consistently. A copper line is not recommended for this application. 3" (76) 21/2" (64) 131/2" (343) FLOOR 3/4" FRONT VIEW (19) BACK WALL 6" (152) 131/2" (343) 21/2" (64) 11/2" (38) 11/2" (38) TOP VIEW 36" (914) models. Plumbing Requirements Water Supply Line 1/4" OD copper, braided stainless steel or PEX tubing Water Pressure 20-100 psi (1.4-6.9 bar) Excess Water Line for Connection 27" (686) 3" (76) 21/2" (64) 9" (229) FLOOR 3/4" FRONT VIEW (19) BACK WALL 6" (152) 9" (229) 21/2" (64) 11/2" (38) 11/2" (38) TOP VIEW 27" (686) models.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Integrated Refrigeration
57
subzero.com/specs
Plumbing Requirements
For integrated models with an automatic ice maker, the
water supply line should be located through the floor or
back wall, within the shaded area shown in the illustra-
tions. The water supply line should be connected to the
house supply with an easily accessible shut-off valve
between the supply and the unit. Do not use self-piercing
valves. A saddle valve kit is available through your author-
ized Sub-Zero dealer.
IMPORTANT NOTE:
It is critical that the water line be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket.
IMPORTANT NOTE:
A reverse osmosis system can be
used provided there is constant water pressure of 20 psi
(1.4 bar)
to 100 psi
(6.9 bar)
supplied to the unit at all times.
In some cases, a reverse osmosis water filter system
may not be able to maintain the minimum pressure
consistently. A copper line is not recommended for this
application.
3"
(76)
9"
(229)
3
/
4
"
(19)
FLOOR
2
1
/
2
"
(64)
FRONT VIEW
27" (686) models.
9"
(229)
6"
(152)
TOP VIEW
1
1
/
2
"
(38)
2
1
/
2
"
(64)
BACK
WALL
1
1
/
2
"
(38)
13
1
/
2
"
(343)
3"
(76)
FRONT VIEW
3
/
4
"
(19)
FLOOR
2
1
/
2
"
(64)
36" (914) models.
13
1
/
2
"
(343)
TOP VIEW
6"
(152)
1
1
/
2
"
(38)
BACK
WALL
2
1
/
2
"
(64)
1
1
/
2
"
(38)
Plumbing Requirements
Water Supply Line
1
/
4
" OD copper, braided stainless steel
or PEX tubing
Water Pressure
20–100 psi
(1.4–6.9 bar)
Excess Water Line for Connection
27"
(686)