TASCAM DA-6400 DA-6400dp Owners Manual Addendum V2.10 - Page 2

New functions in firmware version 2.10

Page 2 highlights

DA-6400/DA-6400dp New functions in firmware version 2.10 The following new functions have been added in firmware version 2.10. 00A cascade function that allows simultaneous recording/playback operations on two units is now supported. 00The INFORMATION screen now shows the cascade status. Cascade function support A cascade function is now supported. This allows simultaneous recording/playback operations with sample-precise synchronization on two units that are connected to the same network. Cascade operation of up to two units is possible with the following simultaneous recording/playback channel limits. 00When the sampling frequency is 44.1/48 kHz, up to 64 channels on 2 units (128 total channels) 00When the sampling frequency is 88.2/96 kHz, up to 32 channels on 2 units (64 total channels) Cascade function setup Use the CASCADE page added to the menu screen to make cascade function settings and check its status. CASCADE STATUS This shows the cascade status. Cascade status Cascade OFF Offline (No Network) ERROR/ALERT classification --- ERROR Offline (Duplicate Slave) ERROR Offline (Duplicate Master) ERROR Comms Lost with Slave ALERT Offline (No Slaves) ALERT Offline (No Master) ERROR Syncing... ERROR Waiting... ERROR OK (N active) --- Contents The cascade function is off. Cascade operation is not possible because it is not connected to a network. Proper cascade operation is not possible because multiple units are set to the same cascade slave ID. Cascade operation is not possible because multiple units are set as the cascade master. The cascade master is no longer able to communicate to one of the cascade slaves. Cascade operation is not possible because no unit set to be a cascades slave could be found on the network. Cascade operation is not possible because no unit set to be the cascade master could be found on the network. Cascade synchronization is being prepared. The unit is waiting for cascade to be ready. Cascade synchronization is working properly for N number of units. 2 TASCAM DA-6400/DA-6400dp

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

DA-6400/DA-6400dp
2
TASCAM
DA-6400/DA-6400dp
New functions in firmware version 2.10
The following new functions have been added in firmware version 2.10.
0
A cascade function that allows simultaneous recording/playback operations on two units is now supported.
0
The
INFORMATION
screen now shows the cascade status.
Cascade function support
A cascade function is now supported. This allows simultaneous recording/playback operations with sample-precise synchronization on
two units that are connected to the same network. Cascade operation of up to two units is possible with the following simultaneous re-
cording/playback channel limits.
0
When the sampling frequency is 44.1/48 kHz, up to 64 channels on 2 units (128 total channels)
0
When the sampling frequency is 88.2/96 kHz, up to 32 channels on 2 units (64 total channels)
Cascade function setup
Use the
CASCADE
page added to the menu screen to make cascade function settings and check its status.
CASCADE STATUS
This shows the cascade status.
Cascade status
ERROR/ALERT classification
Contents
Cascade OFF
---
The cascade function is off.
Offline
(No Network)
ERROR
Cascade operation is not possible because it is not connected to a
network.
Offline
(Duplicate Slave)
ERROR
Proper cascade operation is not possible because multiple units are
set to the same cascade slave ID.
Offline
(Duplicate Master)
ERROR
Cascade operation is not possible because multiple units are set as
the cascade master.
Comms Lost with
Slave
ALERT
The cascade master is no longer able to communicate to one of the
cascade slaves.
Offline (No
Slaves)
ALERT
Cascade operation is not possible because no unit set to be a cas-
cades slave could be found on the network.
Offline (No Mas-
ter)
ERROR
Cascade operation is not possible because no unit set to be the cas-
cade master could be found on the network.
Syncing...
ERROR
Cascade synchronization is being prepared.
Waiting...
ERROR
The unit is waiting for cascade to be ready.
OK (N active)
---