TASCAM DA-6400 DA-6400dp Owners Manual Addendum V2.10 - Page 3

Cascade Units, Cascade Setup, Cascade Mode, Cascade Id

Page 3 highlights

DA-6400/DA-6400dp NOTE ii The cascade status is also shown on the INFORMATION screen. ii If the status is anything other than Cascade OFF or OK, the INFO indicator lights red, and an ERROR INFORMATION or ALERT INFORMATION screen appears with an error/alert as shown below. ERROR INFORMATION screen ALERT INFORMATION screen ii If one of the above cascade errors occurs, recording/playback cannot be started. ii If one of the above cascade alerts occurs, recording/playback can be started. if the error is Offline (No Slaves), then only the cascade master unit will operate. CASCADE UNITS This shows the IDs of the cascade units recognized by this unit. Check whether each device is operating with cascade synchronization by looking at its CASCADE STATUS item. Example when MASTER and SLAVE-1 devices are recognized: M S1 Example when no devices are recognized: NONE CASCADE SETUP Use this to set up the cascade function. Select CASCADE SETUP, and press the MULTI JOG dial to open a screen where you can change the cascade function settings. When on APPLY in the last line, press the MULTI JOG dial to confirm the changed settings and return to the Menu Screen. Press the EXIT [PEAK CLEAR] button to cancel the menu operation and return to the Menu Screen. CASCADE MODE This sets the cascade operation mode. Options OFF (default): This disables the cascade function. ON: This enables the cascade function. CASCADE ID This sets the cascade device ID. The cascade ID should always be set to one not used by any other device. Option MASTER (default) SLAVE-01 Meaning Sets this unit as the cascade master. Sets this unit as cascade slave 1. 3 TASCAM DA-6400/DA-6400dp

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

TASCAM
DA-6400/DA-6400dp
3
DA-6400/DA-6400dp
NOTE
i
The cascade status is also shown on the
INFORMATION
screen.
i
If the status is anything other than
Cascade OFF
or
OK
, the
INFO
indicator lights red, and an
ERROR INFORMATION
or
ALERT
INFORMATION
screen appears with an error/alert as shown below.
ERROR INFORMATION
screen
ALERT INFORMATION
screen
i
If one of the above cascade errors occurs, recording/playback cannot be started.
i
If one of the above cascade alerts occurs, recording/playback can be started. if the error is
Offline (No Slaves)
, then only the
cascade master unit will operate.
CASCADE UNITS
This shows the IDs of the cascade units recognized by this unit.
Check whether each device is operating with cascade synchronization by looking at its
CASCADE STATUS
item.
Example when MASTER and SLAVE-1 devices are recognized:
M S1
Example when no devices are recognized:
NONE
CASCADE SETUP
Use this to set up the cascade function.
Select
CASCADE SETUP
, and press the
MULTI JOG
dial to open a screen where you can change the cascade function settings.
When on
APPLY
in the last line, press the
MULTI JOG
dial to confirm the changed settings and return to the Menu Screen.
Press the
EXIT [PEAK CLEAR]
button to cancel the menu operation and return to the Menu Screen.
CASCADE MODE
This sets the cascade operation mode.
Options
OFF
(default): This disables the cascade function.
ON
: This enables the cascade function.
CASCADE ID
This sets the cascade device ID.
The cascade ID should always be set to one not used by any other device.
Option
Meaning
MASTER
(default)
Sets this unit as the cascade master.
SLAVE-01
Sets this unit as cascade slave 1.