TASCAM EZ CONNECT wner s Manual - Page 28
Operating multiple MX-8A units with TASCAM EZ CONNECT, Connection example using two MX-8A units
View all TASCAM EZ CONNECT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
3 - TASCAM EZ CONNECT Operating multiple MX-8A units with TASCAM EZ CONNECT Multiple MX-8A units can be operated with TASCAM EZ CONNECT. The following conditions are necessary, however, to control MX-8A units with TASCAM EZ CONNECT. 1 Make the area names set on multiple MX-8A the same. 2 Make the passwords set on multiple MX-8A the same. 3 Only put one check mark (4) in "Visible target volume and mute" for each area. Proper operation is not possible if check marks (4) are put into more than one. 4 When setting the input sources for source selection, do not set the same number source selection for multiple MX-8A units. For example, if one MX-8A has source selection 1 set to ANALOG IN 1, set source selection 1 to OFF on other MX-8A units. 5 Do not use the same number for the VOLUME setting with multiple MX-8A units. Connection example using two MX-8A units MX-8A (A) ANALOG INPUTS 1/2 (ANALOG IN 1/2) ANALOG OUTPUTS 3 (MIX 3) EZ CONNECT page settings for MX-8A unit A EZ CONNECT page settings for MX-8A unit B USB (USB IN 1/2) MX-8A (B) ANALOG INPUTS 5 (ANALOG IN 5) ANALOG INPUTS 6 ANALOG INPUTS 7 (ANALOG IN 6) (ANALOG IN 7) ANALOG OUPUTS 7/8 (ANALOG OUT 7/8) NOTE TASCAM EZ CONNECT can operate the following Dante compact processor series. ii MM-2D-E, MM-2D-X ii MM-4D/IN-E, MM-4D/IN-X ii ML-4D/OUT-E, ML-4D/OUT-X For details, see the TASCAM DCP CONNECT operation manual. TASCAM EZ CONNECT screens when the above settings are made TASCAM MX CONNECT 28