APPENDIX D: S-REGISTERS S-Registers, "ATSn=x" Register Dec. S0= 0 - 255 S1= 0 - 255 S2= 0 - 255 S3= 0 - 127 S4= 0 - 127 S5= 0 - 32, 127 S6= 2 - 65 4 - 65 S7= 1 - 255 35 - 59 S8= 0 - 65 Function & Description Default Set the number of the rings required 000 before the modem automatically answers a call. Set "S0=0" to disable auto-answer mode Count the incoming rings and store the 000 value to this register. The value of this register is incremented with each ring. If no rings occur over an 8 sec. interval, this register is cleared. User can read but should not change this value S2 holds the decimal value of the ASCI 043 character used as the escape character. The default value (043) corresponds to an ASCII character "+". A value of 128 to 255 disables the escape process, i.e., no escape character will be recognized Hold the decimal value of the Carriag 013 Return character used as th command line and result code terminator Pertain to asynchronous operation only Hold the decimal value of the character 010 recognized as a line feed. The line feed control character is output after the carriage return control character if verbose result code are used. Hold the decimal value of the character 008 recognized as a backspace. The modem will not recognize the backspace character if this register is set to a value greater than 32 Set the length of time, in seconds, that the modem must wait (minimum 2 seconds even if the value is less than 2) after going off-hook before dialing the first digit of the telephone number For international version 002 For Japanese version 004 Set the time, in seconds, that the modem must wait before hanging up because carrier is not detected For international version 050 For Japanese version 050 Set the time, in seconds, that the 002 modem must pause when the "," dial 1-28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

1-28
APPENDIX D: S-REGISTERS
S-Registers, “ATSn=x”
Register
Dec.
Function & Description
Default
S0=
0 - 255
Set the number of the rings required
before the modem automatically answers
a call. Set “S0=0” to disable auto-answer
mode
000
S1=
0 - 255
Count the incoming rings and store the
value to this register. The value of this
register is incremented with each ring. If
no rings occur over an 8 sec. interval,
this register is cleared. User can read but
should not change this value
000
S2=
0 - 255
S2 holds the decimal value of the ASCI
character used as the escape character.
The default value (043) corresponds to
an ASCII character “+”. A value of 128
to 255 disables the escape process, i.e.,
no escape character will be recognized
043
S3=
0 - 127
Hold the decimal value of the Carriag
Return
<CR>
character
used
as
th
command line and result code terminator
Pertain to asynchronous operation only
013
S4=
0 - 127
Hold the decimal value of the character
recognized as a line feed. The line feed
control character is output after the
carriage return control character if
verbose result code are used.
010
S5=
0 - 32,
127
Hold the decimal value of the character
recognized as a backspace. The modem
will
not
recognize
the
backspace
character if this register is set to a value
greater than 32
008
S6=
Set the length of time, in seconds, that
the modem must wait (minimum 2
seconds even if the value is less than 2)
after going off-hook before dialing the
first digit of the telephone number
2 - 65
For international version
002
4 - 65
For Japanese version
004
S7=
Set the time, in seconds, that the
modem must wait before hanging up
because carrier is not detected
1 - 255
For international version
050
35 - 59
For Japanese version
050
S8=
0 - 65
Set the time, in seconds, that the
modem must pause when the “,” dial
002