TRENDnet TFM-560R Manual - Page 29

Attempt MNP mode. If MNP fails, Fall back to an async connection

Page 29 highlights

S10= 1 - 255 S11= 50 - 150 S12= 0 - 255 S28= 0 - 255 S30= 0 - 90 S36= 0, 2 1, 3 4, 6 5, 7 S37= 0 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 modifier is encountered in the dial string Set the length of time, in tenths of a 020 second, that the modem waits before hanging up after a loss of carrier DTMF duration and inter digit delay. 095 Set the duration and spacing, in miniseconds, in DTMF touch tine dialing Define the maximum period, in 2- 050 hundredths of a second, allowed between consecutive asynchronous escape character "+" (plus) for the escape sequence to be considered valid V.34 modulation en-/disabler 001 0: disabled 1- 255: enabled Inactivity timer. Set the length of time, in 000 minutes, that the modem counts when there is no data flow in or out the DTE serial port. A connection is disengaged when the counter reaches the preset value Set S30 =0 to disable the inactivity timer. For buffer mode only. Negotiation fallback options 007 Hang up Fall back to an async connection Attempt MNP mode. If MNP fails, hang up. Attempt MNP mode. If MNP fails, fallback to async connection. Desired DCE speed (line speed) 000 Maximum modem speed Attempt 1200/75 bps connection Attempt to a 300 bps connection Attempt to a 1200 bps connection Attempt to a 2400 bps connection Attempt to a 4800 bps connection Attempt to a 7200 bps connection Attempt to a 9600 bps connection Attempt to a 12000 bps connection Attempt to a 14400 bps connection Attempt to a 16800 bps connection Attempt to a 19200 bps connection Attempt to a 21600 bps connection Attempt to a 24000 bps connection Attempt to a 26400 bps connection Attempt to a 28800 bps connection 1-29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

1-29
modifier is encountered in the dial
string
S10=
1 - 255
Set the length of time, in tenths of a
second, that the modem waits before
hanging up after a loss of carrier
020
S11=
50 - 150
DTMF duration and inter digit delay.
Set the duration and spacing, in mini-
seconds, in DTMF touch tine dialing
095
S12=
0 - 255
Define the maximum period, in 2-
hundredths
of
a
second,
allowed
between
consecutive
asynchronous
escape character “+” (plus) for the
escape sequence to be considered valid
050
S28=
0 - 255
V.34 modulation en-/disabler
0: disabled
1- 255: enabled
001
S30=
0 - 90
Inactivity timer. Set the length of time, in
minutes, that the modem counts when
there is no data flow in or out the DTE
serial port. A connection is disengaged
when the counter reaches the preset value
Set S30 =0 to disable the inactivity timer.
For buffer mode only.
000
S36=
Negotiation fallback options
007
0, 2
Hang up
1, 3
Fall back to an async connection
4, 6
Attempt MNP mode. If MNP fails,
hang up.
5, 7
Attempt MNP mode. If MNP fails,
fallback to async connection.
S37=
Desired DCE speed (line speed)
000
0
Maximum modem speed
2
Attempt 1200/75 bps connection
3
Attempt to a 300 bps connection
5
Attempt to a 1200 bps connection
6
Attempt to a 2400 bps connection
7
Attempt to a 4800 bps connection
8
Attempt to a 7200 bps connection
9
Attempt to a 9600 bps connection
10
Attempt to a 12000 bps connection
11
Attempt to a 14400 bps connection
12
Attempt to a 16800 bps connection
13
Attempt to a 19200 bps connection
14
Attempt to a 21600 bps connection
15
Attempt to a 24000 bps connection
16
Attempt to a 26400 bps connection
17
Attempt to a 28800 bps connection