Thermador PRG305WH Instructions for Use - Page 8

Important Safety Instructions

Page 8 highlights

9 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS WARNING Before servicing or cleaning the unit, switch power off at service panel and lock service panel. This will prevent power from being switched on accidentally. When the service panel cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. Gas type verification Natural gas - 7 in. water column (17.4 mb) min., 14 in. (34.9 mb) maximum Propane gas - 11 in. water column (27.4 mb) min., 14 in. (34.9 mb) maximum Verify the type of gas supplied to the location. Ensure that the appliance is connected to the type of gas for which it is certified. Refer to the data rating plate. WARNING If a gas conversion kit is used, the kit shall be installed by qualified technician in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in the instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified technician is responsible for the proper installation of the kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with the kit. CAUTION When connecting the unit to propane gas, make certain the propane gas tank is equipped with its own highpressure regulator in addition to the pressure regulator supplied with the appliance. The maximum gas pressure to this appliance must not exceed 14.0'' water column (34.9 mb) from the propane gas tank to the pressure regulator. For Massachusetts installations: 1. Installation must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region where this appliance is being installed. 2. Shut-off valve must be a "T" handle gas cock. 3. Flexible gas connector must not be longer than 36'' (914 mm). Ensure proper installation and servicing. Follow the Installation Instructions provided with this product. Have the appliance installed and electrically grounded by a qualified technician. In the event a burner goes out and gas escapes, open a window or a door. DO NOT attempt to use the appliance until the gas has had time to dissipate. Wait at least 5 minutes before using the appliance. DO NOT repair or replace any part of the appliance unless specifically recommended in this manual. All servicing should be referred to an authorized service provider. Electrical requirements WARNING IN CASE OF AN ELECTRICAL FAILURE If for any reason a gas control knob is turned ON and there is no electrical power to operate the electronic igniters on the burners, turn OFF the gas control knob and wait 5 minutes for the gas to dissipate before lighting the burner manually. To light the burners manually, carefully hold a lighted match to the burner ports and turn the gas control knob to HI. During a power failure, you can use the standard burners, but each must be lit with a match. DO NOT attempt to light the XLO® burners manually. These burners are equipped with the ExtraLow® feature and cannot be lit manually. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, NFPA 70 or the Canadian Electric Code, CSA C22.1-02. WARNING Never Operate the Top Surface Cooking Section of this Appliance Unattended • Failure to follow this warning statement could result in fire, explosion, or burn hazard that could cause property damage, personal injury, or death. • If a fire should occur, keep away from the appliance and immediately call your fire department. DO NOT ATTEMPT TO EXTINGUISH AN OIL/GREASE FIRE WITH WATER. Page. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Page. 6
9
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING
Before servicing or cleaning the unit, switch power off at
service panel and lock service panel. This will prevent
power from being switched on accidentally. When the
service panel cannot be locked, securely fasten a
prominent warning device, such as a tag to the service
panel.
Gas type verification
Natural gas –
7 in. water column (17.4 mb) min., 14 in.
(34.9 mb) maximum
Propane gas –
11 in. water column (27.4 mb) min., 14 in.
(34.9 mb) maximum
Verify the type of gas supplied to the location. Ensure that
the appliance is connected to the type of gas for which it
is certified. Refer to the data rating plate.
WARNING
If a gas conversion kit is used, the kit shall be installed by
qualified technician in accordance with the manufacturer’s
instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in the
instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing
property damage, personal injury or loss of life. The
qualified technician is responsible for the proper
installation of the kit. The installation is not proper and
complete until the operation of the converted appliance is
checked as specified in the manufacturer’s instructions
supplied with the kit.
CAUTION
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the appliance. The maximum gas pressure
to this appliance must not exceed 14.0'' water column
(34.9 mb) from the propane gas tank to the pressure
regulator.
For Massachusetts installations:
1.
Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified or
licensed by the state, province or region where this
appliance is being installed.
2.
Shut-off valve must be a “T” handle gas cock.
3.
Flexible gas connector must not be longer than 36''
(914 mm).
Ensure proper installation and servicing. Follow the
Installation Instructions provided with this product. Have
the appliance installed and electrically grounded by a
qualified technician.
In the event a burner goes out and gas escapes, open a
window or a door.
DO NOT
attempt to use the appliance
until the gas has had time to dissipate. Wait at least 5
minutes before using the appliance.
DO NOT
repair or replace any part of the appliance unless
specifically recommended in this manual. All servicing
should be referred to an authorized service provider.
Electrical requirements
WARNING
IN CASE OF AN ELECTRICAL FAILURE
If for any reason a gas control knob is turned
ON and there is no electrical power to operate
the electronic igniters on the burners, turn OFF
the gas control knob and wait 5 minutes for the
gas to dissipate before lighting the burner
manually.
To light the burners manually, carefully hold a lighted
match to the burner ports and turn the gas control knob
to HI
.
During a power failure, you can use the standard
burners, but each must be lit with a match.
DO NOT
attempt to light the XLO
®
burners manually.
These burners are equipped with the ExtraLow
®
feature
and cannot be lit manually.
The appliance must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, NFPA 70 or the
Canadian Electric Code, CSA C22.1-02.
WARNING
Never Operate the Top Surface Cooking Section of this
Appliance Unattended
Failure to follow this warning statement could result
in fire, explosion, or burn hazard that could cause
property damage, personal injury, or death.
If a fire should occur, keep away from the appliance
and immediately call your fire department. DO NOT
ATTEMPT TO EXTINGUISH AN OIL/GREASE FIRE
WITH WATER.