Toshiba 50H81 Service Manual - Page 16
Circuit Checks, Voltage, Check, Caution, Circuit, Anode, Measuring, Method - power supply
View all Toshiba 50H81 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS CIRCUIT CHECKS HIGH VOLTAGE CHECK CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below. 1. Connect an accurate high voltage meter to the anode of the picture tube. 2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST to minimum (zero beam current). 3. High voltage must be measured below (B) kV. Refer to table-1 for high voltage (B). (See SETTING & ADJUSTING DATA on page 17) 4. Vary the BRIGHTNESS to both extremes to be sure the high voltage does not exceed the limit under any conditions. CAUTION: When the following parts fail, check the High Voltage after replacing. Location No. T461 C407 C408 C441 C432 C433 Name Flyback Capacitor Capacitor Capacitor Capacitor Capacitor Descriptions 50" TFB3090AD 4700pF, ±3% 8200pF, ±5% 4700pF, ±5% 8200pF, ±5% 1200pF, ±3% ANODE VOLTAGE MEASURING METHOD CAUTION: Take extra precaution when measuring this high voltage. High voltages are also present in surrounding circuit boards (CRT DRIVE assembly, DEFLECTION assembly, and POWER SUPPLY assembly). 1. Disconnect the FBT anode cable as outlined below. Measure high voltage at the point where the cable enters the FBT. 2. Holding the rubber cover firmly, turn it counterclockwise and check that the lock has been disengaged. (See Fig. b on page 8.) 3. Determine the extent of the rubber cover before disconnecting the cable. 4. Pull straight up the anode cable to disconnect. 5. When reconnecting the cable, proceed in the reverse order. After reconnecting, tug on the cable to check that it is secure. FS CIRCUIT CHECK The Fail Safe (FS) circuit check is indispensable for the final check in servicing. Checking should be done following the steps below. 1. Turn the receiver on. 2. Temporarily short TP- (R) and TP- (X) on the DEF/POWER Board with a jumper wire. Raster and sound will disappear. 3. The receiver must remain in this state even after removing the jumper wire. This is the evidence that the FS circuit is functioning properly. 4. To obtain a picture again, temporarily turn the receiver off and allow the FS circuit more than 5 seconds to reset. Then turn the receiver on to produce a normal picture. Troubleshooting Guide for Fail Safe Circuit Check that the set returns to normal operation when pin 12 of Z801 is grounded with jumper wire. YES NO Check the voltage across Capacitor C419 is approximately (C) volts. Refer to table -4 for fall safe voltage (C) . Faulty power circuit or horizontal circuit. YES (See SETTING & ADJUSTING DATA on page 17) NO Defective Fail Safe Circuit - 16 -