Toshiba Satellite Pro U300 Maintenance Manual - Page 60
Power Supply Troubleshooting, Procedure 1, Power Status Check
View all Toshiba Satellite Pro U300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
2 Troubleshooting Procedures 2.3 Power Supply Troubleshooting The power supply controller controls many functions and components. To determine if the power supply is functioning properly, start with Procedure 1 and continue with the other Procedures as instructed. The procedures described in this section are: Procedure 1: Power Status Check Procedure 2: Error Code Check Procedure 3: Connection Check Procedure 4: Charging Check Procedure 5: Replacement Check Procedure 1 Power Status Check The following LED indicates the power supply status: Battery LED DC IN LED The Power Supply control displays the power supply status with the Battery LED and the DC IN LED as listed in the tables below. Table 2-1 Battery icon Battery icon Lights orange Lights blue Blinks orange (even intervals) Blinks orange once (at being switched on) Doesn't light Power supply status Battery is charged and the external DC is input. It has no relation with ON/OFF of the system power. Battery is fully charged and the external DC is input. It has no relation with ON/OFF of the system power. The battery level is low while the system power is ON. The system is driven by only a battery and the battery level is low. Any condition other than those above. 8 Manual(960-Q08) Satellite U300 and Satellite Pro U300 Maintenance