Toshiba TLP-S40 User Manual - Page 21

Lamp replacement, Lens and main unit cleaning - service manual

Page 21 highlights

Lens and main unit cleaning WARNING • Request cleaning and maintenance of a ceiling-mounted unit from your projector dealership. I Lens cleaning • Clean the lens with a commercially available blower and/or lens cleaner. • The lens is easily scratched, so do not rub it with hard objects, or strike it. I Main unit cleaning • Clean the main unit after unplugging the power cord. • Wipe dirt off the main unit gently with a soft cloth. • If the soiling is severe, dip the cloth in a neutral detergent diluted in water, wring well, and gently wipe off the dirt, then finish up by wiping with a dry cloth. G Replacing air intake and exhaust fans, and air filter To maintain the performance, it is recommended that these should be replaced about every 2 to 3 years. Consult with your dealer for details. Lamp replacement A lamp is consumable supplies. If used for extended periods, images will appear dark, and the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime of the lamp depends on condition of use. If this happens, replace it with a new one. WARNING • If the projector is mounted on a ceiling, request a lamp replacement from your projector dealership. • When replacing, always use lamp "TLPLV2" (sold separately). CAUTION • If you have been using the projector, the lamp will be very hot, and may cause burn injuries. Wait for the lamp to cool (for longer than 1 hour) before replacing it. • If the lamp should break, please handle with care to avoid injury due to broken pieces and contact your dealer for repair service. 1 Unplug power cord. 2 Wait until lamp is sufficiently cooled. Wait for at least 1 hour. 40 Lamp replacement (Continued) 3 Remove the lamp cover. Loosen the 2 screws, then pull up to the direction of the arrow with your fingers on the area shown in the figure to remove the lamp cover. 3 1 2 4 Pull out the lamp. Loosen the 2 screws holding the lamp in place, and pull up the handle to remove the lamp. 5 Mount the new lamp. 4 1 Align the orientation, press down until the bottom is 2 reached, and lock in place using the two lamp locking screws. 6 Replace the lamp cover. Align the cover, and press it in, then tighten the 2 screws loosened in step 3 until the lamp cover is no longer loose. 5 1 7 Reset the lamp timer. See the lamp's manual for instructions on resetting the lamp timer. Notes and Precautions • Press the button twice to display (a rough guide) the time of lamp use, the Lamp time item, in the Status display menu. p.30 • It is recommended that the lamp should be replaced after 3,000 hours of use. When Lamp time reaches 3,000 hours, the icon and a message will appear. This display disappears when you press button. • Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the lamp may fail to come on p.42 , and the lamp's lifetime may be shortened. • Always replace the lamp with a new one. • The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.) Used Lamps This projector's lamps contain trace amounts of environmentally harmful inorganic mercury. Be careful not to break used lamps, and dispose it in accordance with local regulations. 41 Maintenance

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

41
Maintenance
40
3
Remove the lamp cover.
Loosen the 2 screws, then pull up to the
direction of the arrow with your fingers on the
area shown in the figure to remove the lamp
cover.
4
Pull out the lamp.
Loosen the 2 screws holding the lamp in place,
and pull up the handle to remove the lamp.
5
Mount the new lamp.
Align the orientation, press down until the bottom is
reached, and lock in place using the two lamp
locking screws.
6
Replace the lamp cover.
Align the cover, and press it in, then tighten the
screws loosened in step
3
until the lamp cover is
no longer loose.
7
Reset the lamp timer.
See the lamp
s manual for instructions on resetting
the lamp timer.
Notes and Precautions
Press the
button twice to display (a rough guide) the time of lamp use, the
Lamp time
item, in the
Status display menu
.
p.30
It is recommended that the lamp should be replaced after 3,000 hours of use. When
Lamp time
reaches 3,000 hours, the
icon and a message will appear. This display
disappears when you press
button.
Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the
lamp may fail to come on
p.42
, and the lamp
s lifetime may be shortened.
Always replace the lamp with a new one.
The lamp is made out of glass. Do not touch the glass surface with your bare hands,
bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)
Used Lamps
This projector
s lamps contain trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose it in accordance with local
regulations.
2
1
2
1
1
2
3
4
5
Lamp replacement (Continued)
WARNING
Request cleaning and maintenance of a ceiling-mounted unit from your projector dealership
.
Lens cleaning
Clean the lens with a commercially available blower and/or
lens cleaner.
The lens is easily scratched, so do not rub it with hard objects,
or strike it.
Main unit cleaning
Clean the main unit after unplugging the power cord.
Wipe dirt off the main unit gently with a soft cloth.
If the soiling is severe, dip the cloth in a neutral
detergent diluted in water, wring well, and gently wipe
off the dirt, then finish up by wiping with a dry cloth.
Replacing air intake and exhaust fans, and air filter
To maintain the performance, it is recommended that these should be replaced about
every 2 to 3 years. Consult with your dealer for details.
Lamp replacement
A lamp is consumable supplies. If used for extended periods, images will appear dark, and
the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime
of the lamp depends on condition of use. If this happens, replace it with a new one
.
WARNING
If the projector is mounted on a ceiling, request a lamp replacement from your projector dealership.
When replacing, always use lamp
TLPLV2
(sold separately).
CAUTION
If you have been using the projector, the lamp will be very hot, and may cause burn injuries
.
Wait for the lamp to cool (for longer than 1 hour) before replacing it.
If the lamp should break, please handle with care to avoid injury due to broken pieces
and contact your dealer for repair service.
1
Unplug power cord.
2
Wait until lamp is sufficiently cooled.
Wait for at least 1 hour.