Tripp Lite 9PXEBM180RT Eaton 9PX3K3U and 9PX EBM 180 V Installation and User M - Page 14
Display functions, User settings
View all Tripp Lite 9PXEBM180RT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
2. Presentation 2.6 Display functions Press the Enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the Enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Main menu Measurements Submenu Control Settings Event log Fault log Identification Go to Bypass Start battery test Reset fault state Restore factory set Reset average power Reset cumul. power Dry contacts test Local settings In/Out settings On/Off settings Battery settings Event filter Event list Reset event list Fault list Reset fault list Register product Display information or Menu function [Load] W VA A pf / [Input/Bypass] V Hz / [Output/Efficiency] V Hz / [Battery] % min V n° / [DCbus] V / [Average power usage] Wh / [Cumulat. power usage] Wh since date Transfers the UPS on Bypass mode Starts a manual battery test Clears active fault Returns all settings to original values Clears average power usage measurement Clears cumulated power usage measurement Tests dry contact relay outputs Sets product general parameters Sets Output parameters Sets On/Off conditions Sets battery configuration Selects faults, alarms and/or events to display Displays the events stored Clears events Displays the faults stored Clears faults [Product type/model] / [Part/Serial number] / [UPS/NMC firmware] / [Com card IPv4], [Com card IPv6], [Com card MAC] / [Detected accessories] Links to Eaton registration website 2.7 User settings The following table displays the options that can be changed by the user. Local settings In/Out settings Submenu Available settings Language [English] [Français] [Deutsch] [Español Português] [Italiano] Menus, status, notices and alarms, UPS fault, Event Log data and settings are in all supported languages. Date/ time Format: [International] [US] LCD Modify LCD screen brightness and contrast to be adapted to room light conditions. Audible alarm [Enabled] [Disabled on battery] [Always disabled] Enable or disable the buzzer if an alarm occurs. Output voltage [200V] [208V] [220V] [230V] [240V] Can be changed only in Standby mode Output frequency Frequency converter: [Enabled] [Disabled] Frequency settable in frequency converter mode Output mode [Industrial] [Network] Set UPS behavior regarding transfer on Bypass Input volt hysteresis Sets input voltage hysteresis from 1 to 10V High Efficiency [Enabled] [Disabled] mode Power the output from Bypass for high efficiency Bypass transfer [Transfer if BP AC NOK] [Enabled] [Disabled] Allow transfer on Bypass out of tolerance Default settings [English] User selectable when UPS is powered for the first time. [US] [Enabled] [208V] Disabled [Network] [10V] [Disabled] [Disabled] Page 14 9PX3K3U_EN