9. Specifications Table 6. Electrical output All models Voltage regulation Efficiency Frequency regulation Nominal output Frequency Output overload Output overload (Bypass mode) Voltage waveform Harmonic distortion Transfer time Power factor Load crest ratio Normal mode Battery mode ±1% ±1% > 98% (High Efficiency mode) > 93% > 91% Sync with line ±5% of nominal line frequency (outside this range: ±0.5% of auto-selected nominal frequency) ±0.5% of auto-selected nominal frequency 200/208/220/230/240V (voltage configurable) 3000VA 3000W 50 or 60Hz, autosensing or configurable as a frequency converter 100-102% : no alarm 102-110% : load transfers to Bypass mode after 2 minutes 110-125% : load transfers to Bypass mode after 1 minute 125-150% : load transfers to Bypass mode after 10s > 150% : load transfers to Bypass mode after 500ms 100-125% : no alarm 125-150% : UPS shuts down after 1 minute > 150% : UPS shuts down after 1s Sinewave < 2% THDV on linear load < 5% THDV on non-linear load Online mode: 0 ms (no break) High Efficiency mode: 10ms maximum (due to loss of utility) 1 3 to 1 Table 7. Electrical output connections Model Output connection 9PX3K3U Hardwired (2) L6-30R (2) L6-20R Table 8. Environmental and safety EMC certifications EMC (Emissions)* EMC (Immunity) * for output cable < 10m. IEC/EN 62040-1: 2008 IEC/EN 62040-2: 2006 Cat. C2 IEC/EN 62040-3: 2011 IEC 60950-1 UL 1778 4th CSA 22.2 CISPR22 Class A AS/NZS 22 Class A IEC 61000-3-2 (-3-12) IEC 61000-3-3 (-3-11) FCC part 15 Class A IEC 61000-2-2 IEC 61000-4-2, Level 3 IEC 61000-4-3, Level 3 IEC 61000-4-4, Level 4 (also on signal ports) IEC 61000-4-5, Level 4, Criteria B IEC 61000-4-6, Level 3 IEC 61000-4-8, Level 4 IEC 61000-4-11 Page 42 9PX3K3U_EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Page 42
9PX3K3U_EN
9. Specifications
Table 6. Electrical output
All models
Normal mode
Battery mode
Voltage regulation
±1%
±1%
Efficiency
> 98% (High Efficiency mode)
> 93%
> 91%
Frequency regulation
Sync with line ±5% of nominal line
frequency (outside this range: ±0.5%
of auto-selected nominal frequency)
±0.5% of auto-selected nominal
frequency
Nominal output
200/208/220/230/240V (voltage configurable)
3000VA 3000W
Frequency
50 or 60Hz, autosensing or configurable as a frequency converter
Output overload
100-102% : no alarm
102-110%
: load transfers to Bypass mode after 2 minutes
110-125%
: load transfers to Bypass mode after 1 minute
125-150%
: load transfers to Bypass mode after 10s
> 150%
: load transfers to Bypass mode after 500ms
Output overload
(Bypass mode)
100-125% : no alarm
125-150%
: UPS shuts down after 1 minute
> 150%
: UPS shuts down after 1s
Voltage waveform
Sinewave
Harmonic distortion
< 2% THDV on linear load
< 5% THDV on non-linear load
Transfer time
Online mode: 0 ms (no break)
High Efficiency mode: 10ms maximum (due to loss of utility)
Power factor
1
Load crest ratio
3 to 1
Table 7. Electrical output connections
Model
Output connection
9PX3K3U
Hardwired
(2) L6-30R
(2) L6-20R
Table 8. Environmental and safety
EMC certifications
IEC/EN 62040-1: 2008
IEC/EN 62040-2: 2006 Cat. C2
IEC/EN 62040-3: 2011
IEC 60950-1
UL 1778 4
th
CSA 22.2
EMC (Emissions)*
CISPR22 Class A
AS/NZS 22 Class A
IEC 61000-3-2 (-3-12)
IEC 61000-3-3 (-3-11)
FCC part 15 Class A
EMC (Immunity)
IEC 61000-2-2
IEC 61000-4-2, Level 3
IEC 61000-4-3, Level 3
IEC 61000-4-4, Level 4 (also on signal ports)
IEC 61000-4-5, Level 4, Criteria B
IEC 61000-4-6, Level 3
IEC 61000-4-8, Level 4
IEC 61000-4-11
*
for output cable < 10m.