Tripp Lite SU5000RT4UHV Owner's Manual for SmartOnline Single-Phase 5kVA-6kVA - Page 16

Startup Self-Test, Failed Self-Test

Page 16 highlights

Operation (continued) Startup Self-Test When you turn the UPS ON, it will enter Diagnostic Mode and perform a brief self-test lasting about 15 seconds. The results of the self-test are shown on the LCD screen in the sequence below. STARTED WITH AC INPUT COLD START* *Note: If the UPS is cold started, its BATTERY LED will be lit. DIAGNOSTIC MODE FREQ OUT = 50Hz  DIAGNOSTIC MODE INPUT 000V / 00Hz  DIAGNOSTIC MODE RECTIFIER OK  DIAGNOSTIC MODE CHARGER OK  DIAGNOSTIC MODE BATTERY OK  DIAGNOSTIC MODE DC BUS OK  DIAGNOSTIC MODE INVERTER TEST  DIAGNOSTIC MODE INVERTER OK  LOAD LEVEL 00.00KW / 000% DIAGNOSTIC MODE FREQ OUT = 50Hz  DIAGNOSTIC MODE INPUT 000V / 00Hz  DIAGNOSTIC MODE RECTIFIER OK  DIAGNOSTIC MODE BATTERY OK  DIAGNOSTIC MODE DC BUS OK  DIAGNOSTIC MODE INVERTER TEST  DIAGNOSTIC MODE INVERTER OK  LOAD LEVEL 00.00V / 000% Failed Self-Test If a problem is detected during the self-test, the LCD will display an error message. If your UPS displays any of the following messages in its LCD, visit www.tripplite.com/support for service. BAD BATTERY! CALL FOR SERVICE CHARGE BATT FAIL! CALL FOR SERVICE AC/DC FAILURE! CALL FOR SERVICE INVERTER FAILURE! CALL FOR SERVICE OUTPUT FAILURE! CALL FOR SERVICE FAN FAILURE! CALL FOR SERVICE 16 201207113 933070.indb 16 9/17/2012 1:20:07 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

16
Operation
(continued)
Startup Self-Test
When you turn the UPS ON, it will enter Diagnostic Mode and perform a brief self-test lasting about 15 seconds. The results of the
self-test are shown on the LCD screen in the sequence below.
Failed Self-Test
If a problem is detected during the self-test, the LCD will display an error message. If your UPS displays any of the following
messages in its LCD, visit www.tripplite.com/support for service.
*Note: If the UPS is cold started,
its BATTERY LED will be lit.
STARTED WITH
AC INPUT
COLD
START*
BAD BATTERY!
CALL FOR SERVICE
CHARGE BATT FAIL!
CALL FOR SERVICE
AC/DC FAILURE!
CALL FOR SERVICE
INVERTER FAILURE!
CALL FOR SERVICE
OUTPUT FAILURE!
CALL FOR SERVICE
FAN FAILURE!
CALL FOR SERVICE
DIAGNOSTIC MODE
FREQ OUT = 50Hz
DIAGNOSTIC MODE
FREQ OUT = 50Hz
DIAGNOSTIC MODE
INPUT 000V / 00Hz
DIAGNOSTIC MODE
INPUT 000V / 00Hz
DIAGNOSTIC MODE
RECTIFIER OK
DIAGNOSTIC MODE
RECTIFIER OK
DIAGNOSTIC MODE
CHARGER OK
DIAGNOSTIC MODE
BATTERY OK
DIAGNOSTIC MODE
BATTERY OK
DIAGNOSTIC MODE
DC BUS OK
DIAGNOSTIC MODE
DC BUS OK
DIAGNOSTIC MODE
INVERTER TEST
DIAGNOSTIC MODE
INVERTER TEST
DIAGNOSTIC MODE
INVERTER OK
DIAGNOSTIC MODE
INVERTER OK
LOAD LEVEL
00.00KW / 000%
LOAD LEVEL
00.00V / 000%