ViewSonic Pro9520WL PRO9510L User Guide English - Page 90
Appendix II, RS-232C Protocol
View all ViewSonic Pro9520WL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
APPENDIX II RS-232C Protocol RS232 Setting Baud Rate Data Bits Parity Check Stop Bits Flow Control UART16550 FIFO 9600 8 None 1 None Disable Minimum delay for next command: 1ms Control Command Structure The command is structured by the Header code, command code, data code and end code. Most of the commands are structured except some for the compatibility issue with other projectors. HEX ASCII Header code 'V' Command code Data code End code Command Data 0Dh Command Data CR Operation Command Note: "CR" mean Carriage Return XX=99 Ex: S99S001 + enter , To power on. Return Result P=Pass / F=Fail n: 0:Disable/1: Enable/Value(0~9999) Command Group 00 ASCII HEX Function Description Return Result SXXS0001 53h Xh Xh 53h 30h 30h 30h 31h 0Dh Power On P/F SXXS0002 53h Xh Xh 53h 30h 30h 30h 32h 0Dh Power Off P/F SXXS0003 53h Xh Xh 53h 30h 30h 30h 33h 0Dh Resync P/F SXXG0004 53h Xh Xh 47h 30h 30h 30h 34h 0Dh Get Lamp Hours Pn/F SXXG0005 53h Xh Xh 47h 30h 30h 30h 35h 0Dh Get Air filter timer n=0~999999 Pn/F SXXS0006 53h Xh Xh 53h 30h 30h 30h 36h 0Dh SXXG0007 53h Xh Xh 47h 30h 30h 30h 37h 0Dh SXXG0008 53h Xh Xh 47h 30h 30h 30h 38h 0Dh System Reset 0: Reset Get System Status 1:Standby 2:Operation 3:Cooling Get F/W Version P/F Pn/F Pn/F SXXG0009 53h Xh Xh 47h 30h 30h 30h 39h 0Dh SXXS0009n 53h Xh Xh 53h 30h 30h 30h 39h nh 0Dh SXXS0010 53h Xh Xh 53h 30h 30h 31h 30h 0Dh Get Alter EMail Pn/F Set Alter Email n=xxxxxx@xxxx. xxx.xx P/F Lamp Hours Reset Pn/F 77