Viking VDR548 Installation Instructions

Viking VDR548 Manual

Viking VDR548 manual content summary:

  • Viking VDR548 | Installation Instructions - Page 1
    Installation Professional Freestanding Ranges
  • Viking VDR548 | Installation Instructions - Page 2
    Table of Contents Warnings & Important Safety Instructions 3 Dimensions 6 Specifications 8 Clearance Dimensions (Proximity to Cabinet 10 Clearance Dimensions (Wood/Composite Final Installation 24 Door Replacement 25 Final Preparation 26 Performance Checklist 26 Service & Registration 27 2
  • Viking VDR548 | Installation Instructions - Page 3
    Gas Code ANSI Z223.1 INFPA54. • The installer must leave these instructions with the consumer who should retain for local inspector's use and for is very important. We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages. This
  • Viking VDR548 | Installation Instructions - Page 4
    or moisture. • Viking Range, LLC will NOT warranty any problems resulting from GFI IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, instructions. -If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service
  • Viking VDR548 | Installation Instructions - Page 5
    DANGER GAS LEAK HAZARD To avoid risk of personal injury or death; leak testing of the appliance must be conducted according to the manufacturer's instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution. • DO NOT USE AN OPEN FLAME TO CHECK FOR GAS
  • Viking VDR548 | Installation Instructions - Page 6
    Dimensions 30" and 36" W. Models (3951-.17/c8m") 29-7/8" (75.9 cm) 1" (2.5 cm) (9(9143.15c3mc-t77mo/"m8ma"xin.).) 48" and 60" W. Models (1427(11-.756/268c.04m""c) m) Note: Unit shown with standard island trim. 6 1" (2.5 cm) (913.15c-t7mo/)8m" in. (94 37" cm) max.
  • Viking VDR548 | Installation Instructions - Page 7
    Dimensions Side View 8-1/8" (20.6 cm) 28-1/16" (71.2 cm) 26-7/16" (67.2 cm) 1-5/8" (4.1 cm) 1" (2.5 cm) 35-7/8" (91 cm min.) to 37" (94 cm max.) 19-3/8" (49.2 cm) 24-5/16" (61.8 cm) 25-3/4" (65.4 cm) 45-1/8" (114.6 cm) Note: Unit shown with standard island trim. 7
  • Viking VDR548 | Installation Instructions - Page 8
    or LP/Propane, accepts standard residential 1/2" (1.3 cm) ID gas service line. Unit is field convertible with proper conversion kit Natural 5.0" : Below cooking surface (36" [91.4 cm] and below) • Sides - 0" • Top grate support - 36" (91.4 cm) Above cooking surface (above 36" [91.4 cm]) • Sides -
  • Viking VDR548 | Installation Instructions - Page 9
    Overall AHAM Oven volume Overall AHAM Approximate shipping weight C/VDR548 C/VDR560 47-7/8" (121.6 cm) 60" ( residential 1/2" (1.3 cm) ID gas service line. Unit is field convertible with " [91.4 cm] and below) • Sides - 0" • Top grate support - 36" (91.4 cm) Above cooking surface (above 36" [91.4
  • Viking VDR548 | Installation Instructions - Page 10
    Clearance Dimensions (Proximity to Cabinets) • This range may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. IMPORTANT: The side trim MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by raising the unit using the adjustment
  • Viking VDR548 | Installation Instructions - Page 11
    of the hood being 66" (167.6 cm) to 72" (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. WoodO/Cveormlapyosite ((7611268672""t..mmo69 accinmmx..)) WoodO/Cveormlapyosite
  • Viking VDR548 | Installation Instructions - Page 12
    propane (LP) gas. Before beginning installation verify that the model is compatible with the intended gas supply. Manual shut-off valve: This installer-supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it can be reached quickly in
  • Viking VDR548 | Installation Instructions - Page 13
    Pressure Regulator: • All heavy-duty, commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation, since service pressure may fluctuate with local demand. External regulators are not required on this range since a regulator is
  • Viking VDR548 | Installation Instructions - Page 14
    operation. If you notice the cooling fan is not operating or you observe unusual or excessive noise coming from the cooling fan, contact an Authorized Service Center before continuing operation. Failure to do so can result in damage to the oven or surrounding cabinets. DO NOT use the handle or oven
  • Viking VDR548 | Installation Instructions - Page 15
    Door Removal 1 2 step Open door completely. 3 Fold latches backward until locked in place. 4 Slowly close until latches stop door. Lift door up and out. 15
  • Viking VDR548 | Installation Instructions - Page 16
    Leg Installation 1 2 step step 1 1 3 2 Legs are packed in cardboard top pack. Note: Legs should be installed near to where appliance is to be used, as they are not secure for long transit. Note: It is strongly recommended that a pallet or lift jack be used rather than tilting. Raise unit
  • Viking VDR548 | Installation Instructions - Page 17
    Electrical Connection (3-wire) Note: If you have a 4-wire connection, see following section for 4-wire connection instructions. WARNING Electrical shock hazard. To avoid risk or electrical shock, personal injury or death; grounding product to the frame of the unit may or may
  • Viking VDR548 | Installation Instructions - Page 18
    Electrical Connection (3-wire con't) 4 5 1 Attach line #1 (red) and line #2 (black) leads to outside terminal. Attach neutral wire (white) to center terminal on the terminal block. 6 Push supply cord toward terminal block to relieve strain, reattach supply cord strain relief bracket over supply
  • Viking VDR548 | Installation Instructions - Page 19
    Electrical Connection (4-wire) 1 2 Remove access door. 3 Remove supply cord strain relief bracket and three supply cord mounting screws on the terminal block. 4 Remove grounding screw. Cut-off and discard ground strap. 5 Feed supply cord up through hole in bottom of range back. 6 Attach
  • Viking VDR548 | Installation Instructions - Page 20
    Electrical Connection (4-wire con't) 7 1 8 Push supply cord toward terminal block to relieve strain, reattach supply cord strain relief bracket over supply cord. Reattach access door. Leveling/Adjustments/Alignment 1 2 Measure the four corners in cutout area to verify if flooring is level.
  • Viking VDR548 | Installation Instructions - Page 21
    Installation 3 4 step step step Move unit into opening. 5 0.95 cm Check that unit is level side to side and front to back. Side trim of the lowest corner must be 3/8" (0.95 cm) above countertop. 6 step If leveling is required, move unit out of opening. 7 1 1 2 Lift unit and prop on wood
  • Viking VDR548 | Installation Instructions - Page 22
    HAZARD To reduce the risk of property damage or personal injury; install anti-tipping device provided in accordance with the installation instructions in this document. Device must be engaged properly to prevent product from tipping over. Measurement (A) step 2 Y X Me+a1s/u2r"e(m1.e3nctm
  • Viking VDR548 | Installation Instructions - Page 23
    Installation Anti-tip Device Installation (Floor Mount) 1 1-1/4" + B* A Ø(.321/c8m") Locate anti-tip bracket hook on the floor Dim A from side cabinet and 11/4" (3.2 cm) from rear wall when using an island trim or high shelf. If using an 8" (20.3 cm) backguard, add Dim B to the 1-1/4". Mark and
  • Viking VDR548 | Installation Instructions - Page 24
    leak testing of the appliance must be conducted according to the manufacturer's instructions. Before placing appliance in operation, always check for gas leaks with by your dealer, a qualified licensed plumber, or gas service company. Standoff Spacer Removal DANGER FIRE HAZARD Backguards come
  • Viking VDR548 | Installation Instructions - Page 25
    . Place burner bases on top of the burner flanges and burner heads on top of the burner base. Place burner grate on top of grate support. Door Replacement 00..9955 ccmm Check that unit is level side to side and front to back. The side trim must be 3/8" (0.95 cm) above
  • Viking VDR548 | Installation Instructions - Page 26
    Final Preparation • All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, DO NOT use steel wool, abrasive cloths, cleansers, or powders! If it is necessary to scrape stainless steel to remove encrusted materials,
  • Viking VDR548 | Installation Instructions - Page 27
    on the back side of the range. Record the following information indicated below. You will need it if service is ever required. Model number Serial number Date of purchase Date installed Dealer's name Address These installation instructions should remain with the unit for future reference. 27
  • Viking VDR548 | Installation Instructions - Page 28
    Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit vikingrange.com 062679-000A EN (013018)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Installation
Professional Freestanding Ranges