Viking VDR548 Installation Instructions - Page 12

Electrical & Gas Requirements

Page 12 highlights

Electrical & Gas Requirements Electrical Requirements - Gas Ranges This product is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, agency approved, power supply kit with closed loop terminals rated per the National Electrical Code, ANSI/NFPA 70-latest edition (See Rating chart below). If local codes prohibit grounding through the neutral, use a 4-wire, agency approved, power supply kit with closed loop terminals rated per the National Electrical Code, ANSI/NFPA 70-latest edition (See Rating chart below). The range is designed specifically for natural gas or liquid propane (LP) gas. Before beginning installation verify that the model is compatible with the intended gas supply. Manual shut-off valve: This installer-supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it can be reached quickly in the event of an emergency. Any opening behind the range shall be sealed. RATING* Specified Rating of Power Supply Cord Kit and Circuit Protection 120/240 Volts 120/208 Volts Amps 12.5 - 16.5 KW 9.2 - 12.5 KW 40 or 50 16.5 - 17.5 KW 12.5 - 13.5 KW 50 *The National Electric Code calculation for Electrical Load is less than the Total Connected Electrical Load listed on the model/serial rating plate. In Massachusetts: A "T" handle type manual valve must be installed in the gas supply line to the appliance. Gas Connection The gas supply (service) line must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" (1.3 cm) ID NPT (Sch40) inlet. Sealant on all pipe joints must be resistive to LP gas. WARNING ELECTRICAL SHOCK HAZARD To avoid the risk of electrical shock, personal injury or death; verify electrical power is turned off at the breaker box and gas supply is turned off until the range is installed and ready to operate, installation by an authorized installer only. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

12
Electrical Requirements - Gas Ranges
This product is manufactured with the
neutral terminal connected to the cabinet.
Use a 3-wire, agency approved, power
supply kit with closed loop terminals rated
per the National Electrical Code, ANSI/NFPA
70-latest edition (See Rating chart below). If
local codes prohibit grounding through the
neutral, use a 4-wire, agency approved,
power supply kit with closed loop terminals
rated per the National Electrical Code,
ANSI/NFPA 70-latest edition (See Rating
chart below).
RATING* Specified Rating of Power
Supply Cord Kit and Circuit Protection
120/240 Volts
120/208 Volts
Amps
12.5 - 16.5 KW
9.2 - 12.5 KW
40 or 50
16.5 - 17.5 KW
12.5 - 13.5 KW
50
*The National Electric Code calculation for
Electrical Load is less than the Total
Connected Electrical Load listed on the
model/serial rating plate.
Gas Connection
The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. This range uses a 1/2” (1.3 cm) ID
NPT (Sch40) inlet. Sealant on all pipe joints must
be resistive to LP gas.
The range is designed specifically for
natural gas or liquid propane (LP) gas.
Before beginning installation verify that
the model is compatible with the
intended gas supply.
Manual shut-off valve:
This installer-supplied valve must be
installed in the gas service line before the
appliance in the gas stream and in a
location where it can be reached quickly in
the event of an emergency. Any opening
behind the range shall be sealed.
In Massachusetts:
A “T” handle type
manual valve must be installed in the gas
supply line to the appliance.
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box and gas supply is turned off until
the range is installed and ready to operate,
installation by an authorized installer only.
Electrical & Gas Requirements