Page 6 highlights
PROXIMITY TO SIDE CABINET INSTALLATION (24" W. MODELS) 1. This range may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop. This may be accomplished by raising the unit using the adjustment spindles on the legs. 2. The range CANNOT be installed directly adjacent to combustible sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above the 36" (91.4 cm) counter height. There must be a minimum of 6" (15.2 cm) side clearance for the 4-Burner, Griddle and Wok model ranges and a minimum of 9" (22.9 cm) side clearance for the Char-Grill model to such combustible surfaces above the 36" (91.4 cm) cm) counter height. 3. Within the side clearance to combustible vertical surfaces above 36" (91.4 cm), the maximum wall cabinet depth must be 13" (33.0 cm) and wall cabinets within this side clearance must be 18" (45.7 cm) above the 36" (91.4 cm) high countertop. 4. Wall cabinets above the range must be a minimum of 42" (106.7 cm) above the range cooking surface for the full width of the range. This minimum requirement does not apply if a rangehood is installed over the cooking surface. 4B Model G Model K Model Q Model A 6" (15.2 cm) 6" (15.2 cm) 6" (15.2 cm) 9" (22.9 cm) 42" 13" (106.7 cm) (33.0 cm) Min. Max. (6203.67c/8m") A 36" (91.4 cm) 18" (45.7 cm) Min. 3/8" (0.95 cm) PROXIMITY TO SIDE CABINET INSTALLATION (30" W., 36" W., 48" W., 60" W. MODELS) 1. This range may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop. This may be accomplished by raising the unit using the adjustment spindles on the legs. 2. The range CANNOT be installed directly adjacent to combustible sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above the 36" (91.4 cm) counter height. There must be a minimum of 6" (15.2 cm) side clearance from the range to such combustible surfaces above the 36" (91.4 cm) counter height. 3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm), the maximum wall cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm) above the 36" (91.4 cm) high countertop. 4. Wall cabinets above the range must be a minimum of 36" (91.4 cm) for open top burners and a minimum of 42" (106.7 cm) for sealed burner models above the range cooking surface for the full width of the range. This minimum height requirement does not apply if a rangehood is installed over the cooking surface. Dim. A 30" W. Models 29 7/8" (75.9 cm) 36" W. Models 35 7/8" (91.1 cm) 48" W. Models 47 7/8" (121.6 cm) 60" W. Models 59 1/2" (151.1 cm) Open Top Burners Sealed Burners Dim. B (minimum) 36" (91.4 cm) 42" (106.7 cm) B 13" (33.0 cm) Max. 6" (15.2 cm) A Min 36" (91.4 cm) 18" (45.7 cm) Min. 3/8" (0.95 cm) Adjustable spindles 10 Adjustable spindles 11
![](/manual_guide/products/viking-vgic2454bss-installation-instructions-99f1c67/6.png)