Viking VGR548 Installation Instructions - Page 11
Wood/Composite Overlay
![]() |
View all Viking VGR548 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Clearance Dimensions (Wood/Composite Overlay) The bottom of a standard hood should be 30" (76.2 cm) min. to 36" (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66" (167.6 cm) to 72" (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. WoodO/Cveormlapyosite ((7611268672""t..mmo69 accinmmx..)) WoodO/Cveormlapyosite (612.04"cm) (00c"m) 33((796061""..t24mmoccaimmnx.)). ((7611268672""t..mmo69 accinmmx..)) Island Installation (763.20"cm) (156.2"cm) 33((796061""..t24mmoccaimmnx.)). Wall Installation Note: Minimum clearance for back wall is 0" with backguard or highshelf. Note: This range comes standard with an Island Trim. There must be a minimum of 6" (15.2 cm) clearance from rear of range to a combustible wall or 0" clearance to a non-combustible wall. Note: Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified by CSA. Clearances to non-combustible materials must be approved by the authority having jurisdiction. 11