Weslo Momentum G 3.1 Elliptical English Manual - Page 15
Maintenance And Troubleshooting - belt
View all Weslo Momentum G 3.1 Elliptical manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. Next, carefully pull the Right Shield (4) outward and upward until you can reach the Idler Adjustment Bolt (34). Be careful to avoid scratching the Right Shield on the Right Thin Locknuts (36). CONSOLE TROUBLESHOOTING Most console problems are the result of low batteries. See assembly step 12 on page 11 for replacement instructions. 36 HOW TO ADJUST THE DRIVE BELT If you can feel the pedals slip while you are pedaling, even when the resistance is adjusted to the highest level, the drive belt may need to be adjusted. To adjust the drive belt, first remove the three indicated ST4.2 x 12mm Self-tapping Screws (66) and the three indicated ST4.2 x 20mm Self-tapping Screws (68). 4 7 34 70 19 68 4 Next, loosen the M10 Nut (70), and turn the Idler 66 Adjustment Bolt (34) counterclockwise until the Drive Belt (19) is tight. Then, retighten the Nut. 68 66 See the drawing at the left. Reattach the Right Shield (4) with the three ST4.2 x 12mm Self-tapping Screws (66) and the three ST4.2 x 20mm Self-tapping Screws (68). 68 66 15