Whirlpool GI6SDRXXB User Instructions - Page 15

Performance, Datasheet

Page 15 highlights

PERFORMANCDEATASHEET Interior Water Filtration System Model UKF8001AXX-200 Capacity 200 Gallons (757 Liters) Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, (_ SMyesrtceumry, teAstteradzinea,nd Bceenrtzifeiende, bpy-DNicShFloroInbteenrnzaetnioen, al Cagaarbinosfut raNn,SF/AToNxSaIpheSntea,ndaCrdysts4,2 Tfourrbtihdeity,redAuscbtieosntos,of O-Dichlorobenzene, Ethylbenzene, Chlorobenzene, Endrin, Tetrachloroethylene and Lindane. This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53. Substance Reduction Aesthetic Effects NSF Reduction Requirements Average Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum% Average% Reduction Reduction Chlorine Taste/Odor Particulate Class I* 50% reduction 85% reduction 2.00 mg/L 2.0 mg/L + 10% 14,000,000 #/mL At least 10,000 particles/mL 0.06 mg/L 370,000 #/mL** 0.050625 mg/L 97.00% 196,666 #/mL 97.40% 97.52% 99.00% Contaminant Reduction NSF Reduction Requirements Average Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum% Average% Reduction Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 0.010 mg/L 0.010 mg/L 0.150 mg/U 0.150 mg/U 0.15 mg/L + 10% 0.15 mg/L _+10% < 0.001 mg/L < 0.001 mg/L < 0.001 mg/L < 0.001 mg/L >99.30% >99.30% >99.30% >99.30% Mercury: @ pH 6.5 Mercury: @ pH 8.5 0.002 mg/L 0.002 mg/L 0.006 mg/L 0.0059 mg/L 0.006 mg/L + 10% 0.006 mg/L _+10% 0.0005 mg/L 0.0018 mg/L 0.0003 mg/L 0.00073 mg/L 91.70% 69.20% 95.00% 88.10% Benzene 0.005 mg/L 0.0133 mg/L 0.015 mg/L _+10% 0.0005 mg/L 0.0005 mg/L 96.10% 96.30% p-Dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L _+10% < 0.0005 mg/L < 0.0005 mg/L >99.80% >99.80% Carbofuran 0.040 mg/L 0.0753 mg/L 0.08 mg/L _+10% 0.027 mg/L 0.008 mg/L 64.60% 73.45% Toxaphene 0.003 mg/L 0.015 mg/L 0.015 _+10% < 0.001 mg/L < 0.001 mg/L >93.3% >93.3% Atrazine Asbestos 0.003 mg/L >99% 0.0102 mg/L 126.5 MF/L 0.009 mg/L _+10% 107to 108fibers/L t_ 0.0027 mg/L < 0.17 MF/L 0.00105 mg/L < 0.17 MF/L 76.30% >99.99% 89.40% >99.99% Live Cysts _ Turbidity >99.95% 0.5 NTU 122,500 #/L 10.5 NTU 50,000/L min. 11 _+1 NTU < 1 #/U 0.30 NTU < 1 #/U 0.125 NTU >99.99% 97.30% >99.99% 98.80% Lindane 0.0002 mg/L 0.0019 mg/L 0.002 _+10% < 0.00016 mg/L 0.000035 mg/L 91.80% 97.90% Tetrachloroethylene 0.005 mg/L 0.015 mg/L 0.015 mg/L _+10% < 0.0005 mg/L < 0.0005 mg/L >96.6% >96.6% O-Dichlorobenzene 0.6 mg/L 1.7 mg/L 1.8 mg/L _+10% < 0.5 mg/L < 0.5 mg/L >99.9% >99.9% Ethylbenzene 0.7 mg/L 2.2 mg/L 2.1 mg/L _+10% 0.0048 mg/L 0.11 mg/L 99.80% 99.90% Chlorobenzene 0.1 mg/L 2.0 mg/L 2.0 mg/L _+10% 0.0038 mg/L 0.0008 mg/L 99.80% 99.90% Endrin 0.002 mg/L 0.007 mg/L 0.006 mg/L _+10% 0.0004 mg/L 0.0002 mg/L 94.30% 96.80% Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.55 gpm (2.08 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F _+5°F (20°C _+3°C). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. • Refer to the "Warranty" section for the Manufacturer's limited warranty. The disposable water filter should be replaced at least every 6 months. The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter's rated life is used, the yellow (Order) light comes on. When 100% of the filter's rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use replacement filter model UKF8001AXX-200. 2010 suggested retail price of $44.99 U.S.A./S49.95 Canada. Prices are subject to change without notice. Application Water Supply Water Pressure Water Temperature Service Flow Rate Guidelines/Water Supply Parameters City or Well 35 - 120 psi (241 - 827 kPa) 33 ° - 100°F (1° - 38°C) 0.55 gpm (2.08 L!min.) @ 60 psi • The product is for cold water use only. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. • Refer to the "Water Filtration System" section for the Manufacturer's name and telephone number. *Class I particle size: >0.5 to

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

PERFORMANCE
DATASHEET
Interior
Water
Filtration
System
Model
UKF8001AXX-200
Capacity
200
Gallons
(757
Liters)
(_
System
tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the
reduction
of
Chlorine
Taste and
Odor,
Particulate
Class
I*; and
against
NSF/ANSI
Standard
53 for the
reduction
of Lead,
Mercury,
Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts,
Turbidity,
Asbestos,
O-Dichlorobenzene,
Ethylbenzene,
Chlorobenzene,
Endrin,
Tetrachloroethylene
and
Lindane.
This
system
has
been
tested
according
to
NSF/ANSI
Standards
42 and
53 for
the
reduction
of
the
substances
listed
below.
The
concentration
of the
indicated
substances
in water
entering
the
system
was
reduced
to
a concentration
less
than
or equal
to
the
permissible
limit
for
water
leaving
the
system,
as specified
in NSF/ANSI
Standards
42 and
53.
Substance
Reduction
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.00 mg/L
2.0 mg/L
+ 10%
0.06 mg/L
0.050625
mg/L
97.00%
97.52%
Particulate
Class
I*
85% reduction
14,000,000
#/mL
At least 10,000
370,000
#/mL**
196,666
#/mL
97.40%
99.00%
particles/mL
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.150
mg/U
0.15 mg/L + 10%
< 0.001
mg/L
< 0.001 mg/L
>99.30%
>99.30%
Lead: @ pH 8.5
0.010 mg/L
0.150
mg/U
0.15 mg/L _+10%
< 0.001
mg/L
< 0.001 mg/L
>99.30%
>99.30%
Mercury:
@ pH 6.5
0.002 mg/L
0.006
mg/L
0.006 mg/L
+ 10%
0.0005 mg/L
0.0003
mg/L
91.70%
95.00%
Mercury:
@ pH 8.5
0.002 mg/L
0.0059
mg/L
0.006 mg/L
_+10%
0.0018 mg/L
0.00073
mg/L
69.20%
88.10%
Benzene
0.005
mg/L
0.0133
mg/L
0.015 mg/L
_+10%
0.0005 mg/L
0.0005
mg/L
96.10%
96.30%
p-Dichlorobenzene
0.075
mg/L
0.210 mg/L
0.225 mg/L
_+10%
< 0.0005
mg/L
< 0.0005
mg/L
>99.80%
>99.80%
Carbofuran
0.040 mg/L
0.0753
mg/L
0.08 mg/L _+10%
0.027 mg/L
0.008
mg/L
64.60%
73.45%
Toxaphene
0.003 mg/L
0.015
mg/L
0.015 _+10%
< 0.001
mg/L
< 0.001 mg/L
>93.3%
>93.3%
Atrazine
0.003 mg/L
0.0102
mg/L
0.009 mg/L
_+10%
0.0027 mg/L
0.00105
mg/L
76.30%
89.40%
Asbestos
>99%
126.5 MF/L
107to 108fibers/L t_
< 0.17
MF/L
< 0.17 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
122,500 #/L
50,000/L
min.
< 1 #/U
< 1 #/U
>99.99%
>99.99%
Turbidity
0.5 NTU
10.5 NTU
11 _+1 NTU
0.30 NTU
0.125
NTU
97.30%
98.80%
Lindane
0.0002
mg/L
0.0019
mg/L
0.002 _+10%
< 0.00016
mg/L
0.000035
mg/L
91.80%
97.90%
Tetrachloroethylene
0.005 mg/L
0.015
mg/L
0.015 mg/L
_+10%
< 0.0005
mg/L
< 0.0005
mg/L
>96.6%
>96.6%
O-Dichlorobenzene
0.6 mg/L
1.7 mg/L
1.8 mg/L
_+10%
< 0.5 mg/L
< 0.5 mg/L
>99.9%
>99.9%
Ethylbenzene
0.7 mg/L
2.2 mg/L
2.1 mg/L
_+10%
0.0048 mg/L
0.11 mg/L
99.80%
99.90%
Chlorobenzene
0.1 mg/L
2.0 mg/L
2.0 mg/L
_+10%
0.0038 mg/L
0.0008
mg/L
99.80%
99.90%
Endrin
0.002 mg/L
0.007
mg/L
0.006 mg/L
_+10%
0.0004 mg/L
0.0002
mg/L
94.30%
96.80%
Test Parameters:
pH = 7.5
It is essential that operational,
maintenance,
and filter replacement
requirements
be carried
out for the product
to perform
as advertised.
The disposable
water filter should
be replaced
at least every
6 months.
The filter monitor
system
measures
the amount
of water that passes
through
the filter and alerts you to replace the filter. When 90% of the
filter's rated life is used, the yellow
(Order) light comes
on. When
100%
of the filter's rated life is used, the red (Replace) light comes
on,
and it is recommended
that you replace the filter. For models
without
filter status
lights, replace the filter every 6 months.
Use replacement
filter model
UKF8001AXX-200.
2010 suggested
retail price of
$44.99
U.S.A./S49.95
Canada.
Prices are subject
to change
without
notice.
_+0.5 unless otherwise
noted.
Flow = 0.55 gpm
(2.08 Lpm).
Pressure = 60 psig
(413.7 kPa). Temp.
= 68°F _+5°F (20°C _+3°C).
Refer to the "Warranty"
section
for the
Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33 ° - 100°F
(1° - 38°C)
Service
Flow Rate
0.55 gpm
(2.08 L!min.) @ 60 psi
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before
or after the system.
Systems
certified
for cyst reduction
may be used on disinfected
waters
that may contain
filterable
cysts.
Refer to the "Water Filtration
System"
section for the Manufacturer's
name and telephone
number.
*Class
I particle
size: >0.5 to <1 um
**Test requirement
is at least 100,000
particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily
in your water supply.
Performance
may vary based on local water conditions.
ttFibers
greater
than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered
trademark
of NSF International.
15