bracket for rear venting d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws. e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws. NOTE: Square metal frame attached to mouth of blower must be installed for proper operation. f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base. g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base.The wiring cable must be properly secured in the 2 clips (see step b.) Reattach blower box to downdraft vent base with 4 hex nuts. WARNING Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury. 10. Insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws. When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened. 11. Attach one undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop. 8. Attach backdraft damper over blower box knockout with 2 Phillips-head screws. WARNING 9. Remove the 2 Phillips-head screws attaching the wiring box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Remove rear or bottom knockout and install conduit connector. 8 Electrical Shock Hazard Disconnect power before servicing. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. 12. Disconnect power. green ground screw wiring box conduit connector 13. Remove required knockout and install conduit connector. Feed the power supply cable through the conduit connector and into the wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) ground wire to eyelet with green ground screw. Tighten the conduit connector clamp screws. Replace the wiring box cover. 14. Reconnect power. microswitches behind filters. ON/OFF button top trim filter or filters depending on model blower control knob end cap 15. Push and hold for a few seconds the button on the top of the downdraft vent. Retractable section of downdraft vent will rise and blower will start. Position the top trim over the retractable section and snap trim into place.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

8
d. Remove screws attaching
brackets to each side of blower.
Reposition brackets on blower
as shown. Then reinstall screws.
e. Reinstall blower in blower box
with mouth of blower pointing
out open side of blower box.
Secure blower to blower box
with 6 Phillips-head screws.
NOTE:
Square metal frame
attached to mouth of blower must
be installed for proper operation.
f. Attach metal cover from parts
bag over down-venting knockout
in blower box. Remove rear
knockout cover on back of vent
base.
g. Reconnect blower wiring cable.
Secure wiring cable in 2 black
plastic clips inside vent
base.The wiring cable must be
properly secured in the 2 clips
(see step b.) Reattach blower
box to downdraft vent base with
4 hex nuts.
bracket for
rear venting
8.
Attach backdraft damper
over blower box knockout with 2
Phillips-head screws.
9.
Remove the 2 Phillips-head
screws attaching the wiring box
cover. Determine which direction
(rear or down) electrical connection
will need to run from appliance
wiring box. Remove rear or bottom
knockout and install conduit
connector.
Excessive Weight Hazard
Use two or more people to move
and install downdraft vent.
Failure to do so can result in back
or other injury.
WARNING
10.
Insert downdraft vent
into countertop cutout. Two people
are recommended to support the
weight of the downdraft vent
during lifting. Position downdraft
vent so it is centered in cutout and
parallel to edge of cutout. Check
that downdraft vent is level
vertically. Then fasten lower
support legs to cabinet floor with
screws.
11.
Attach one undercounter
bracket on front upper right
corner of downdraft vent with slot
over vent mounting hole and
flange against countertop. Attach
other bracket to left side of
downdraft vent. Carefully drill
starter holes through
undercounter mounting brackets
into underside of countertop.
Insert appropriate length screws
into holes and tighten brackets to
countertop.
When attaching undercounter bracket
to underside of countertop, make
sure that the screw length will not go
through countertop when tightened.
Electrical Shock Hazard
Disconnect power before
servicing.
Connect ground wire to green
ground screw in terminal box.
Failure to do so can result in
death or electrical shock.
WARNING
12.
Disconnect power.
13.
Remove required
knockout and install conduit
connector. Feed the power supply
cable through the conduit
connector and into the wiring box.
Connect the white wires together
with a twist-on wire connector.
Connect the black wires together
with a twist-on wire connector.
Attach the green (or green and
yellow) ground wire to eyelet with
green ground screw. Tighten the
conduit connector clamp screws.
Replace the wiring box cover.
14.
Reconnect power.
ON/OFF
button
blower
control
knob
end cap
top trim
filter or filters
depending on
model
microswitches behind filters.
wiring
box
green
ground
screw
conduit
connector
15.
Push and hold for a few
seconds the button on the top of
the downdraft vent. Retractable
section of downdraft vent will rise
and blower will start. Position the
top trim over the retractable
section and snap trim into place.