Whirlpool UXD8630DYS Installation Guide - Page 10

Determine Which Vent Direction Is Best For Your, Installation, Bottom Venting

Page 10 highlights

4. Install the right and left undercounter mounting brackets to the vent box. Slide the keyhole slots over the guide tabs and push the brackets up to set them into place. B A C 7. Attach the support legs to the side of the vent box with 4 - 4 x 8 mm screws in each support leg. Adjust to dimension "Y" from the bottom of the vent box to the bottom of the support legs. Tighten screws. C A D A. Vent box B. Undercounter mounting bracket C. Keyhole slots D. Guide tabs 5. Attach the right and left end caps to the vent box. Place the tab into the mounting slot at each end of the downdraft vent as shown and push down to lock into place. A B A. End cap tab B. Mounting slot 6. Measure distance "X" from the cabinet floor to the top of the countertop. Subtract 28¹⁄₂" from distance "X" to determine dimension "Y" (X - 28¹⁄₂ = Y). Top of countertop Dim. "Y" B A. Motor box B. Support leg C. 4 x 8 mm screws (4) Determine Which Vent Direction Is Best For Your Installation When installed in a cabinet, vent system can exhaust through the bottom, right or left of the cabinet. IMPORTANT: When using the 6" (15.2 cm) vent transition (supplied) for 6" round venting, only left or right venting is recommended. Bottom Venting: NOTE: If installing the vent damper in the down position, a wall or roof cap with a damper at the exit end of the vent system is required. ■ Downdraft vent is shipped with blower in down venting position so no modification is required. ■ If rear mounting of the blower motor is not required, go to the "Complete Installation" section. ■ To mount the blower motor to the rear side of the vent box, go to the "Rear Mounting - Blower Motor" section. Downdraft vent 28¹⁄₂" (73 cm) "X" "Y" Cabinet floor 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

10
4.
Install the right and left undercounter mounting brackets to
the vent box. Slide the keyhole slots over the guide tabs and
push the brackets up to set them into place.
5.
Attach the right and left end caps to the vent box. Place the
tab into the mounting slot at each end of the downdraft vent
as shown and push down to lock into place.
6.
Measure distance “X” from the cabinet floor to the top of the
countertop. Subtract 28
¹⁄₂
" from distance “X” to determine
dimension “Y” (X - 28
¹⁄₂
= Y).
7.
Attach the support legs to the side of the vent box with
4 - 4 x 8 mm screws in each support leg. Adjust to dimension
“Y” from the bottom of the vent box to the bottom of the
support legs. Tighten screws.
Determine Which Vent Direction Is Best For Your
Installation
When installed in a cabinet, vent system can exhaust through the
bottom, right or left of the cabinet.
IMPORTANT:
When using the 6" (15.2 cm) vent transition
(supplied) for 6" round venting, only left or right venting is
recommended.
Bottom Venting:
NOTE:
If installing the vent damper in the down position, a wall or
roof cap with a damper at the exit end of the vent system is
required.
Downdraft vent is shipped with blower in down venting
position so no modification is required.
If rear mounting of the blower motor is not required, go to
the “Complete Installation” section.
To mount the blower motor to the rear side of the vent
box, go to the “Rear Mounting - Blower Motor” section.
A. Vent box
B. Undercounter mounting bracket
C. Keyhole slots
D. Guide tabs
A. End cap tab
B. Mounting slot
B
C
D
A
A
B
Cabinet floor
Top of countertop
Downdraft vent
“X”
“Y”
28
¹⁄₂
"
(73 cm)
A. Motor box
B. Support leg
C. 4 x 8 mm screws (4)
A
B
Dim. “Y”
C