Xerox 6130N User Guide - Page 100
Symptom, Reason/Action, See the Xerox Support website - replace imaging unit
UPC - 095205735475
View all Xerox 6130N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Print-Quality Problems Symptom Toner smears when rubbed Reason/Action The paper is damp. Replace the paper. See About Paper on page 4-5. The paper is outside the recommended specification range. Replace the paper with a recommend size and type, and confirm that your print driver settings are correct. See About Paper on page 4-5. The toner cartridges are not Xerox toner cartridges. Verify that the toner cartridges (C/M/Y/K) meet specifications, and replace if necessary. The fuser is old or damaged. Replace the fuser. Blank pages Two or more sheets may be feeding at once. Remove the paper stack from the tray, fan it, and reinsert it. The toner cartridges are not Xerox toner cartridges. Verify that the toner cartridges (C/M/Y/K) meet specifications, and replace if necessary. The transfer unit is old or damaged. Replace the transfer unit. The high-voltage supply is defective. See the Xerox Support website, www.xerox.com/office/6130support, for assistance. Hair-like marks appear in or around black half-tone printing Shadows appear around areas of dense black printing The paper was left unwrapped for a long time (especially in a dry environment). Replace the paper. See About Paper on page 4-5. The paper is outside the recommended specification range. Replace the paper with a recommended size and type, and confirm that your print driver settings are correct. See About Paper on page 4-5. The transfer unit is old or damaged. Replace the transfer unit. Color around the edge of printing is incorrect The color registration is incorrect. Adjust the color registration. See Color Registration on page 6-6. Colored dots are The imaging unit is dirty. printed at regular Clean the imaging unit. intervals (about 28 mm) Phaser® 6130 Printer 6-4