Yamaha EL-100 Owner's Manual - Page 71

<R.SHIFT&gt, <S.END> ⁄, MODE:USER, POSITION Cursor Controls

Page 71 highlights

4 User Selects the User mode. In the User mode, each press of the Right Footswitch selects registrations according to the order you specify. 1. When you select the User mode, the Shift End selector function, how the Registration Shift function acts when it reaches to the end, will be added to the right side of the display. Also, page number will be shown at the top right side. DATA CONTROL DATA CONTROL ⁄ MODE:USER STOP STOP TOP NEXT SONG 2. Select the Shift End type using the bottom right Data Control buttons. The following three types are available: Stop: Selects the last registration and quits the operation. Top: After reaching the last preset, then selects the first preset again and repeats the operation. NOTE: Always press the PLAY button to start the songs and activate the Next Song function on the M.D.R. The CUSTOM PLAY button will not cause to activate the Next Song function. 5 Registration Memory Next Song: After reaching the last preset, then automatically calls up the registration data of the next song. This function is handy for you to play a song containing more than 16 registrations. Recording the songs onto the M.D.R. using this function allows you to play back them successively. NOTE: Using the Next Song function will not read the User rhythm patterns/sequences while playing back a rhythm. 3. Press the Page buttons to select Page 2. The following display appears. You can edit the registration shift settings of your own here. 1-1 1-4 2-1 2-2 DATA CONTROL DATA CONTROL 1-2 1-3 [INS][DEL]¤ T_1 Cursor 1-2 1-3 1 POSITION (Cursor Controls) 1 -1 Moves the cursor to the first position. 1 -2 Moves the cursor one step to the left. 1 -3 Moves the cursor one step to the right. 1 -4 Moves the cursor to the last position. NOTE: The cursor cannot be moved unless registration numbers have been entered. NOTE: The registration to which the cursor is currently positioned is set on the Electone. However, moving the cursor cannot activate the Shift End function. NOTE: Up to 80 steps can be memorized. Although the number of registrations shown in the display at a time is limited, the display scrolls to the right to show the currently entered registration number as you enter them. NOTE: The Shift End mark will automatically be put at the end of the registrations you entered. N NEXT SONG ¯ TOP 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

Registration Memory
5
71
4
User
Selects the User mode. In the User mode, each press of the Right Footswitch
selects registrations according to the order you specify.
1.
When you select the User mode, the Shift End selector function,
how the Registration Shift function acts when it reaches to the end,
will be added to the right side of the display.
Also, page number
will be shown at the top right side.
<R.SHIFT>
<S.END> ⁄
MODE:USER
STOP
STOP
TOP
NEXT SONG
DATA CONTROL
DATA CONTROL
2.
Select the Shift End type using the bottom right Data Control
buttons.
The following three types are available:
Stop:
Selects the last registration and quits the operation.
Top:
After reaching the last preset, then selects the first preset again
and repeats the operation.
Next Song:
After reaching the last preset, then automatically calls
up the registration data of the next song.
This function is handy for
you to play a song containing more than 16 registrations.
Recording the songs onto the M.D.R. using this function allows you
to play back them successively.
NOTE:
Always press the PLAY button to start the
songs and activate the Next Song function
on the M.D.R.
The CUSTOM PLAY
button will not cause to activate the Next
Song function.
NOTE:
Using the Next Song function will not read
the User rhythm patterns/sequences while
playing back a rhythm.
3.
Press the Page buttons to select Page 2. The following display
appears.
You can edit the registration shift settings of your own
here.
<R.SHIFT>[INS][DEL]¤
T
_
?????????????????
Cursor
DATA CONTROL
DATA CONTROL
1
-1
1
-4
2
-1
2
-2
1
-2
1
-3
1
-2
1
-3
1
POSITION (Cursor Controls)
1
-1
Moves the cursor to the first position.
1
-2
Moves the cursor one step to the left.
1
-3
Moves the cursor one step to the right.
1
-4
Moves the cursor to the last position.
NOTE:
The cursor cannot be moved unless
registration numbers have been entered.
NOTE:
The registration to which the cursor is
currently positioned is set on the Electone.
However, moving the cursor cannot
activate the Shift End function.
NOTE:
Up to 80 steps can be memorized.
Although the number of registrations
shown in the display at a time is limited,
the display scrolls to the right to show the
currently entered registration number as
you enter them.
NOTE:
The Shift End mark will automatically be
put at the end of the registrations you
entered.
N
¯
NEXT SONG
TOP