Yamaha HTR-4063 Owners Manual - Page 26

Message list, When a warning message appears before, measurement, Error message

Page 26 highlights

■ Message list NOTE If the following messages appear, resolve the problems that have occurred and carry out the measurement process again. ■ When a warning message appears before measurement Connect MIC! Unplug HP! Memory Guard! The YPAO microphone is not connected. Connect the YPAO microphone to the YPAO MIC jack on the front panel. The headphones are connected. Remove the headphones. The settings of this unit are protected. Set "Memory Guard" in the Setup menu to "Off" (☞p. 58). ■ Error message E-1:FRONT SP The unit was not able to find the front channel. Check that the left and right front speakers are connected correctly. E-2:SUR. SP The unit was only able to find one of side of the surround channels. Check that the left and right surround speakers are connected correctly. E-4:SBR->SBL Only one surround back speaker is connected and only the right side surround back channel sound is detected. When only one surround back speaker is connected, connect to the left side terminal on the external amplifier. E-5:NOISY The noise is too loud, preventing accurate measurements from being taken. Measure again in quiet surroundings. Turn off any devices in the room that may be emitting noise, or place them further away from the YPAO microphone. When this message is displayed, selecting "Proceed" will allow you to continue measuring. However, we recommend resolving the problem and measuring again, as continuing measurement without doing so will not give accurate results. E-6:CHECK SUR. Even though surround left and right speakers are not connected, only the surround back speakers are connected. When using surround back speakers, connection of the surround left/right speakers is necessary. CONNECTIONS Set up the speaker parameters automatically (YPAO) E-7:NO MIC E-8:NO SIGNAL E-9:CANCEL E-10:INTERNAL The YPAO microphone has been removed. The YPAO microphone could not distinguish a test tone. You have carried out an operation that has cancelled the measuring process. An internal error has occurred. While measuring, take care not to touch the YPAO microphone. Check that the YPAO microphone has been installed correctly. Check that each speaker has been connected and installed correctly. The YPAO microphone or the YPAO MIC jack may be broken. Inquire at the retailer where you purchased this unit, or the nearest Yamaha service center. Carry out the measuring process again. Do not operate this unit by, for example, adjusting the volume. Carry out the measuring process again. Contact a Yamaha service center if "E-10" appears again. En 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

En
26
CONNECTIONS
Set up the speaker parameters automatically (YPAO)
Message list
When a warning message appears before
measurement
Error message
NOTE
If the following messages appear, resolve the problems that have
occurred and carry out the measurement process again.
Connect MIC!
The YPAO microphone is
not connected.
Connect the YPAO
microphone to the YPAO
MIC jack on the front
panel.
Unplug HP!
The headphones are
connected.
Remove the headphones.
Memory Guard!
The settings of this unit
are protected.
Set “Memory Guard” in
the Setup menu to “Off”
(
p. 58
).
E-1:FRONT SP
The unit was not able to
find the front channel.
Check that the left and
right front speakers are
connected correctly.
E-2:SUR. SP
The unit was only able to
find one of side of the
surround channels.
Check that the left and
right surround speakers
are connected correctly.
E-4:SBR->SBL
Only one surround back
speaker is connected and
only the right side
surround back channel
sound is detected.
When only one surround
back speaker is
connected, connect to the
left side terminal on the
external amplifier.
E-5:NOISY
The noise is too loud,
preventing accurate
measurements from
being taken.
Measure again in quiet
surroundings. Turn off any
devices in the room that
may be emitting noise, or
place them further away
from the YPAO
microphone.
When this message is
displayed, selecting
“Proceed” will allow you
to continue measuring.
However, we recommend
resolving the problem and
measuring again, as
continuing measurement
without doing so will not
give accurate results.
E-6:CHECK SUR.
Even though surround
left and right speakers are
not connected, only the
surround back speakers
are connected.
When using surround back
speakers, connection of the
surround left/right
speakers is necessary.
E-7:NO MIC
The YPAO microphone
has been removed.
While measuring, take
care not to touch the
YPAO microphone.
E-8:NO SIGNAL
The YPAO microphone
could not distinguish a
test tone.
Check that the YPAO
microphone has been
installed correctly.
Check that each speaker
has been connected and
installed correctly.
The YPAO microphone
or the YPAO MIC jack
may be broken. Inquire at
the retailer where you
purchased this unit, or the
nearest Yamaha service
center.
E-9:CANCEL
You have carried out an
operation that has
cancelled the measuring
process.
Carry out the measuring
process again. Do not
operate this unit by, for
example, adjusting the
volume.
E-10:INTERNAL
An internal error has
occurred.
Carry out the measuring
process again. Contact a
Yamaha service center if
“E-10” appears again.