Yamaha MG20XU Owner's Manual - Page 35
Rack Mounting, Precautions for Rack Mounting, Mounting Procedures - mixer case
View all Yamaha MG20XU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Appendix Rack Mounting The MG12XU/MG12 require at least 10 U* of rack space. To take into account the cable connections, we recommend to ensure 11 U* of rack space. The MG20XU/MG20/MG16XU/MG16 require at least 12 U* of rack space. To take into account the cable connections, we recommend to ensure 14 U* of rack space. * 10 U is approximately 445 mm, 11 U is approximately 489 mm, 12 U is approximately 533 mm, and 14 U is approximately 623 mm. Precautions for Rack Mounting This unit is rated for operation at ambient temperatures ranging from 0 to 40 degrees Celsius. If you install this unit along with other devices in a poorly ventilated rack, the ambient temperature inside the rack may rise, resulting in inefficient performance. Be sure to rack-mount in the following conditions so the unit does not overheat. • When mounting the unit in a rack with devices such as power amplifiers that generate a significant amount of heat, leave more than 1 U of space between the MG and other equipment. Also, either leave the open spaces uncovered or install appropriate ventilating panels to minimize the possibility of heat buildup. • To ensure sufficient airflow, leave the rear of the rack open and position it at least 10 centimeters from walls or other surfaces. If the rear of the rack cannot be left open, install a commercially available fan or similar ventilating option to secure sufficient airflow. If you've installed a fan kit, there may be cases in which closing the rear of the rack will produce a greater cooling effect. Refer to the rack and/or fan unit manual for details. Rack mount brackets Right and left designation of rack mount brackets MG20XU/ MG20 Accessories - MG16XU/ MG16 Accessories - MG12XU/ MG12 Indicated L/R Option sold separately Model Name: RK-MG12 (Locate the bracket designated 'L' on the left, and the bracket desig- nated 'R' on the right) Mounting Procedures (The illustration shows the MG12XU.) 1. Use a screwdriver to loosen the screws on the rack mount brackets installed on the mixer. 2. Use the screws removed in Step 1 to install the rack mount brackets (included with MG20XU/ MG20/MG16XU/MG16, optional RK-MG12 for the MG12XU/MG12 sold separately) on the mixer. NOTICE Be sure to use the screws removed in Step 1. Using other screws can cause damage. 3. Mount the unit into the rack, and fasten it into place. CAUTION This unit is heavy, and should be lifted by two people when mounting it into a rack. 10 U* 11 U* * The MG20XU/MG20/MG16XU/MG16 require at least 12 U of rack space. To take into account the cable connections, we recommend to ensure 14 U of rack space. MG20XU/MG20/MG16XU/MG16/MG12XU/MG12 Owner's Manual 35