Yamaha SPX900 SPX900 Owners Manual Image - Page 10

Level, Fv0l1, Fv0l2, Balance, Level

Page 10 highlights

EXTERNAL CONTROL ASSIGNMENT The SPX900 allows two different parameters of a selected effect to be controlled by optional foot controllers (Yamaha FC7) connected to the front-panel EXT CTRL/FOOT VOL1 and 2 jacks. The EXT CTRL ASSIGN key is used to assign the desired effect parameters to the foot controllers used, and to set the required control range. External control assignments made for an effect program can' be stored in the user memory area (51 - 99) along with the effect (using the STORE function described above), so that the assignments made are recalled whenever that memory location is selected. 1. Select the desired effect program. 2. Select the parameter to be assigned to an external foot controller (PARAM, LEVEL, EQ or INT PARAM parameters can be assigned). SCROLL C==) ) A BACK PARAM LEVEL t:7D C=IZ) EXT CTRL EQ APAM ASSIGN ; "r REV1 HALL TRG. LEVEL= 0 3. Press the EXT CTRL ASSIGN key. The name of the selected effect program will remain on the upper line of the LCD, and one of the following parameters will appear on the lower line: C=7.7.7 C=.D SCROLL A BACK PARAM LEVEL C=D INT EXT CTRL EQ PARAM REV1 HALL FV0L1 REV TIME In the actual display, "XXXXXXXX" will be the name of the default parameter for the selected effect program. The EXT CTRL ASSIGN key can be used to scroll forward through the above parameters, and the SCROLL BACK key can be used to scroll backwards. 4. To assign the selected parameter to the EXT CTRL/FOOT VOL1 or EXT CTRL/FOOT VOL2 controller, use the EXT CTRL ASSIGN or SCROLL BACK key to call the "FVOL1 XXXXXXXX" or "FVOL2 XXXXXXXX" parameter. 1 SCROLL A BACK PARAM LEVEL ) EQ INT PARAM EXT CTRL AS, M REV1 HALL FV0L2 BALANCE - 6, 5. Press either the parameter or key and the parameter you called within the selected effect program will be assigned to the foot controller indicated on the display (FVOL1 or FVOL2). SCROLL A BACK PARAM LEVEL C:=7.D CZ= INT EXT CTRL EQ PARAM ASSIGN REV1 HALL FV0L2 TRG. LEVEL 6. Use the "MIN" and "MAX" parameters for the appropriate controller to set the control range. If the parameter to be controlled has a range of 0 to 100%, for example, setting the MIN parameter to 20 and the MAX parameter to 80 will allow the foot controller to vary the selected parameter from 20% to 80% of its total range. NOTE: Either or both controllers may be assigned. When both controllers are used, each can be assigned a different parameter within the selected effect program. NOTE. External control assignments will be lost if a different memory location is selected without first storing the assigned effect program into one of the user memory locations (51 - 99) using the STORE function. TE. MIDI control change messages received via the MIDI IN connector can also be used to control assigned parameters. See "MIDI CTRL ASSIGN" on page 29. CAUTION! When setting the range and storing it in the program, always make sure the preset values for the assigned parameters are included within the set range. When setting the range, confirm the values for MIN and MAX with the controller, and always make sure the preset values are inside the externally set values. If the preset values are outside the specified range, there may be no response to the controller when a recall operation is carried out. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

EXTERNAL
CONTROL
ASSIGNMENT
The
SPX900
allows
two
different
parameters
of
a
selected
effect
to
be
controlled
by
optional
foot
controllers
(Yamaha
FC7)
connected
to
the
front
-panel
EXT
CTRL/FOOT
VOL1
and
2
jacks.
The
EXT
CTRL
ASSIGN
key
is
used
to
assign
the
desired
effect
parameters
to
the
foot
controllers
used,
and
to
set
the
required
control
range.
External
control
assignments
made
for
an
effect
program
can'
be
stored
in
the
user
memory
area
(51
99)
along
with
the
effect
(using
the
STORE
function
described
above),
so
that
the
assignments
made
are
recalled
whenever
that
memory
location
is
selected.
1.
Select
the
desired
effect
program.
2.
Select
the
parameter
to
be
assigned
to
an
external
foot
controller
(PARAM,
LEVEL,
EQ
or
INT
PARAM
parameters
can
be
assigned).
SCROLL
C==)
)
A
BACK
PARAM
LEVEL
REV1
HALL
EQ
t:7
D
;
"r
APAM
C=IZ)
EXT
CTRL
ASSIGN
TRG.
LEVEL=
0
3.
Press
the
EXT
CTRL
ASSIGN
key.
The
name
of
the
selected
effect
program
will
remain
on
the
upper
line
of
the
LCD,
and
one
of
the
following parameters
will
appear
on
the
lower
line:
SCROLL
C=.D
C=7.7.7
A
BACK
PARAM
LEVEL
REV1
HALL
C=D
FV0L1
REV
TIME
EQ
INT
PARAM
EXT
CTRL
In
the
actual
display,
"XXXXXXXX"
will
be
the
name
of
the
default
parameter
for
the
selected
effect
program.
The
EXT
CTRL
ASSIGN
key
can
be
used
to
scroll
forward
through
the
above
parameters,
and
the
SCROLL
BACK
key
can
be
used
to
scroll
backwards.
4.
To
assign
the
selected
parameter
to
the
EXT
CTRL/FOOT
VOL1
or
EXT
CTRL/FOOT
VOL2
controller,
use
the
EXT
CTRL
ASSIGN
or
SCROLL
BACK
key
to
call
the
"FVOL1
XXXXXXXX"
or
"FVOL2
XXXXXXXX"
parameter.
1
A
SCROLL
BACK
PARAM
LEVEL
REV1
HALL
FV0L2
BALANCE
-
)
EXT
CTRL
INT
EQ
PARAM
AS
,M
5.
Press
either
the
parameter
6,
or
key
and
the
parameter
you
called
within
the
selected
effect
program
will
be
assigned
to
the
foot
controller
indicated
on
the
display
(FVOL1
or
FVOL2).
A
SCROLL
BACK
PARAM
LEVEL
REV1
HALL
C:=7.D
CZ=
FV0L2
TRG.
LEVEL
INT
EXT
CTRL
EQ
PARAM
ASSIGN
6.
Use
the
"MIN"
and
"MAX"
parameters
for
the
appropriate
controller
to
set
the
control
range.
If
the
parameter
to
be
controlled
has
a
range
of
0
to
100%,
for
example,
setting
the
MIN
parameter
to
20
and
the
MAX
parameter
to
80
will
allow
the
foot
controller
to
vary
the
selected
parameter
from
20%
to
80%
of
its
total
range.
NOTE:
Either
or
both
controllers
may
be
assigned.
When
both
controllers
are
used,
each
can
be
assigned
a
different
parameter
within
the
selected
effect
program.
NOTE.
External
control
assignments
will
be
lost
if
a
different
memory
location
is
selected
without
first
storing
the
assigned
effect
program
into
one
of
the
user
memory
locations
(51
99)
using
the
STORE
function.
TE.
MIDI
control
change
messages
received
via
the
MIDI
IN
connector
can
also
be
used
to
control
assigned
parameters.
See
"MIDI
CTRL
ASSIGN"
on
page
29.
CAUTION!
When
setting
the
range
and
storing
it
in
the
program,
always
make
sure
the
preset
values
for
the
assigned
parameters
are
included
within
the
set
range.
When
setting
the
range,
confirm
the
values
for
MIN
and
MAX
with
the
controller,
and
always
make
sure
the
preset
values
are
inside
the
externally
set
values.
If
the
preset
values
are
outside
the
specified
range,
there
may
be
no
response
to
the
controller
when
a
recall
operation
is
carried
out.
8