ZyXEL P-861H-G2 User Guide - Page 268
VDSL Command Examples
View all ZyXEL P-861H-G2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 268 highlights
Prestige 861H Series User's Guide 32.6 VDSL Command Examples You must type the main command first and then the sub-commands, as follows: P861H> vdsl vdsl> port snr The rest of this chapter shows commonly used VDSL sub-command examples. 32.6.1 VDSL Port Command Syntax: vdsl port snr vdsl port speed vdsl port counter vdsl port clrcntr This command displays the information on your VDSL port SNR(Signal-to-Noise-Ratio), speed and counter. You can also clear the port counter. The examples are shown next Figure 175 VDSL Port Speed Commands Example (Link Down) P861H> vdsl port speed VDSL status : DOWN P861H> Figure 176 VDSL Port Speed Commands Example (Link Up) P861H> vdsl port speed VDSL status : UP Downstream line rate : 72384 kbps Upstream line rate : 44928 kbps Fast Downstream payload rate : 0 kpbs Slow Downstream payload rate : 60864 kpbs Fast Upstream payload rate : 0 kpbs Slow Upstream payload rate : 37440 kpbs Downstream delay : 3.8 ms Uptream delay : 6.2 ms Tx total power 5.9 dbm vdsl> The following table explains these parameters. 267 Chapter 32 VDSL Commands