Brother International BAS-326F-0 Instruction Manual - English - Page 57
BAS-326F-0, 9-10-4. Adjusting the air pressure, Air pressure should be 0.5 MPa.
View all Brother International BAS-326F-0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
9. STANDARD ADJUSTMENTS 9-10-3. BAS-326F-0 1268S (3) (2) (4) (3) (2) (4) (5) (5) (1) 1304S 1269S 20 mm Scale 1270S 1. Turn on the air, and then press the presser lifter switch (1) to raise the presser foot (2) . 2. Loosen the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4). 3. Place a scale against the presser foot (2), and then move presser lifter lever UR (3) and presser lifter lever UL (4) up and down to adjust so that the amount of presser lift is 20 mm from the top of the needle plate. 4. After adjusting the lift amount (20 mm), tighten the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4). 9-10-4. Adjusting the air pressure (2) (4) 1. Air pressure should be 0.5 MPa. The air pressure can be adjusted by pulling up and turning the control knob (2) on the integrator (1). After adjustment is complete, push the control knob (2) downward to lock it. 2. If water stands in the bottle of the integrator (1), turn the drain cock (3) in the direction indicated by an arrow to drain the water. Note Open the air cock (4) slowly. (1) (3) 1271S BAS-311F-0, 311F-L, 326F-0 50