Brother International BAS-326F-0 Instruction Manual - English - Page 72

BAS-311F-0, 311F-L, 326F-0

Page 72 highlights

12. ERROR CODES Code Cause Remedy E.A0 E.A1 E.c0 E.c1 E.c2 E.c3 E.c4 E.c5 E.d0 E.E0 E.E1 E.E2 E.E3 Start switch was pressed when there was no Read sewing data again. sewing available data. Can not detect home position. X-Y feed or Turn off power and, check X-Y feed and connector P1. connection of home position sensor is incorrect. Motor PROM is not correctly inserted. Turn off power and check it. Cooling fan (left one when viewed from front) in Turn off power and check it. Check fan connector. control box does not operate. Heat-sink on main PCB is overheating. Turn off power and clean air inlet port. Overcurrent was detected in X pulse motor. Turn off power and check it. Overcurrent was detected in Y pulse motor. Turn off power and check it. Cooling fan (right one when viewed from front) in Turn off power and check it. Check fan connector. control box does not operate. Air pressure has dropped. If not use detector, set OFF memory switch 1d. Control PROM is not correctly inserted. Turn off power and check it. Main PCB detected communication error. Turn off power and then on again. Panel PCB detected communication error. Turn off power and then on again. Incorrect connection of cable between operation Turn off power and check it. panel and control box. E.F0 Solenoid is short-circuited (malfunction of main Turn off power and check it. circuit board) or power supply relay is not operating (malfunction of power supply circuit board). E.F1 E.F2 Incorrect connection of cable between power supply Turn off power and check connector P20. PCB and main PCB. Over current at power supply PCB. Turn off power and check it. REFERENCE segment LED alphabet Panel display Text display A B C D E F 6 H L O BAS-311F-0, 311F-L, 326F-0 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

12. ERROR CODES
BAS-311F-0, 311F-L, 326F-0
65
Code
Cause
Remedy
E.A0
Start switch was pressed when there was no
sewing available data.
Read sewing data again.
E.A1
Can not detect home position.
X-Y feed or
connection of home position sensor is incorrect.
Turn off power and, check X-Y feed and connector P1.
E.c0
Motor PROM is not correctly inserted.
Turn off power and check it.
E.c1
Cooling fan (left one when viewed from front) in
control box does not operate.
Turn off power and check it.
Check fan connector.
E.c2
Heat-sink on main PCB is overheating.
Turn off power and clean air inlet port.
E.c3
Overcurrent was detected in X pulse motor.
Turn off power and check it.
E.c4
Overcurrent was detected in Y pulse motor.
Turn off power and check it.
E.c5
Cooling fan (right one when viewed from front) in
control box does not operate.
Turn off power and check it.
Check fan connector.
E.d0
Air pressure has dropped.
If not use detector, set OFF memory switch 1d.
E.E0
Control PROM is not correctly inserted.
Turn off power and check it.
E.E1
Main PCB detected communication error.
Turn off power and then on again.
E.E2
Panel PCB detected communication error.
Turn off power and then on again.
E.E3
Incorrect connection of cable between operation
panel and control box.
Turn off power and check it.
E.F0
Solenoid is short-circuited (malfunction of main
circuit board) or power supply relay is not operating
(malfunction of power supply circuit board).
Turn off power and check it.
E.F1
Incorrect connection of cable between power supply
PCB and main PCB.
Turn off power and check connector P20.
E.F2
Over current at power supply PCB.
Turn off power and check it.