Brother International MFC 9760 Service Manual - Page 185
This selector determines whether or not the earth function is added to the transfer setting menu
View all Brother International MFC 9760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
Selector No. 1 2 | 4 5 6 7 8 WSW04 (TRANSFER facility setting) Function Earth function in transfer facility Setting and Specifications 0: Provided 1: Not provided Not used. Earth time length for earth function Break time length for flash function No. 5 6 00 01 10 11 No. 7 8 00 01 10 11 : 200 ms : 300 ms : 500 ms : 700 ms : 80 ms : 110 ms : 250 ms : 500 ms NOTE: Selectors 5 through 8 are not applicable in those countries where no transfer facility is supported. Selector 1: Earth function in transfer facility This selector determines whether or not the earth function is added to the transfer setting menu to be accessed by the function switch. Selectors 5 and 6: Earth time length for earth function These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground. This setting is effective only when the earth function is selected for the R key by using the function switch. Selectors 7 and 8: Break time length for flash function These selectors set the break time length. This setting is effective only when the flash function is selected for the R key by using the function switch. 6