Brother International MFC 9760 Service Manual - Page 214

WSW35 Function setting 13

Page 214 highlights

WSW34 (Function setting 12) Selector No. 1 | 3 4 5 6 7 8 Function Not used. No. of CNG cycles to be detected (when the line is connected via the machine or external telephone in the external TAD mode) Number of DTMF tone signals for inhibiting the detection of CNG during external TAD operation CNG detection when the external telephone is connected with a line in TAD mode Setting and Specifications No. 6 7 0 0 : 0.5 (A) 01 : 1 (B) 1 0 : 1.5 (C) 11 : 2 (D) No. 6 7 00: 01: 10: 11: 3 2 1 OFF 0: Only when the 1: Always equipment detects itself being called NOTE: Selectors 4 and 5 are not applicable to the American version. Selectors 4 and 5: No. of CNG cycles to be detected The machine interprets a CNG as an effective signal if it detects a CNG signal by the number of cycles specified by these selectors when the line is connected via the machine or external telephone except in the external TAD mode. Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external TAD operation If the machine receives this specified number of DTMF tone signals during external TAD operation, it will not detect CNG afterwards. If these selectors are set to "1, 1," the CNG detection will not be inhibited. Selector 8: CNG detection when the external telephone is connected with a line in TAD mode If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being called. If the external telephone is connected with a line before the equipment detects itself being called, the equipment will no longer detect a CNG signal. If this selector is set to "1," the equipment will detect a CNG signal every time the external telephone is connected with a line, even without detecting itself being called. Selector No. 1 | 8 WSW35 (Function setting 13) Function Setting and Specifications Not used. 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255

35
WSW34 (Function setting 12)
Selector
No.
Function
Setting and Specifications
1
|
3
Not used.
4
5
No. of CNG cycles to be detected
(when the line is connected via the
machine or external telephone in the
external TAD mode)
No. 6
7
0
0
:
0.5
(A)
0
1
:
1
(B)
1
0
:
1.5
(C)
1
1
:
2
(D)
6
7
Number of DTMF tone signals for
inhibiting the detection of CNG
during external TAD operation
No. 6
7
0
0
:
3
0
1
:
2
1
0
:
1
1
1
:
OFF
8
CNG detection when the external
telephone is connected with a line
in TAD mode
0:
Only when the
1: Always
equipment detects
itself being called
NOTE:
Selectors 4 and 5 are not applicable to the American version.
±
Selectors 4 and 5:
No. of CNG cycles to be detected
The machine interprets a CNG as an effective signal if it detects a CNG signal by the number of
cycles specified by these selectors when the line is connected via the machine or external
telephone except in the external TAD mode.
±
Selectors 6 and 7:
Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD operation,
it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
±
Selector 8:
CNG detection when the external telephone is connected with a line in TAD mode
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being
called.
If the external telephone is connected with a line before the equipment detects itself being
called, the equipment will no longer detect a CNG signal.
If this selector is set to "1," the equipment will detect a CNG signal every time the external
telephone is connected with a line, even without detecting itself being called.
WSW35 (Function setting 13)
Selector
No.
Function
Setting and Specifications
1
|
8
Not used.