Protocol Number of digits (including check digits and start and stop codes) Characters that can be used EAN128 4 through 22 All ASCII characters CODABAR 4 through 22 Numbers, letters, and symbols and + UPC-E 6 Numbers UPC-A 13 Numbers EAN8 8 Numbers EAN13 13 Numbers I-2/5 Even number of digits* Numbers Notes Start and stop codes must be A, B, C, or D * Two digits are needed to print each part of the data for an 1-2/5 barcode. Therefore, if an odd number of digits are entered, "0" is automatically added at the beginning of the data when the barcode is printed. However, "0" does not appear on the LCD display. To use the barcode function: 1 Hold down Code and press N . Barcode To change the data or parameters of a barcode that has already been created, position the cursor below the barcode mark ( ) before holding down Code and pressing N . Barcode A label can only contain one barcode. If a barcode has already been entered when Code is held down and N is pressed, the error mes- Barcode sage "1 BAR CODE / LABEL" will appear. To quit the barcode function without making any changes, hold down Code and press N . Barcode 2 Type in the new barcode data or edit the old data. To change the barcode parameter settings: 3 Press . Home 49