Compaq ProLiant 7000 SMART-2DH Array Controller Reference Guide - Page 186

Slot x Drive Array - Drives Disabled due to, Slot x Drive Array - Array Accelerator Read

Page 186 highlights

H-11 POST Error Messages continued 1797 Slot x Drive Array - Array Accelerator Read Replace the Array Accelerator or the Error Occurred. Data in Array Accelerator has SMART-2DH Controller. Restore data from been lost. Array Accelerator is disabled. backup. 1798 Slot x Drive Array - Array Accelerator SelfTest Error Occurred. Array Accelerator is disabled. Replace the Array Accelerator or the SMART-2DH Controller. 1799 Slot x Drive Array - Drive(s) Disabled due to Array Accelerator Data Loss. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to reenable logical drives. Data stored in the Array Accelerator has been lost, therefore the drives have been temporarily disabled. Press F2 to acknowledge the data loss and reenable the logical drives. Restore data from backup. SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

H-11
SMART-2DH Array Controller Reference Guide
Writer: Pamela King
Project: SMART-2DH Array Controller Reference Guide
Comments: 295469-002
File Name: O-APPH.DOC
Last Saved On: 2/27/98 12:10 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages
continued
1797
Slot x Drive Array - Array Accelerator Read
Error Occurred. Data in Array Accelerator has
been lost. Array Accelerator is disabled.
Replace the Array Accelerator or the
SMART-2DH Controller. Restore data from
backup.
1798
Slot x Drive Array - Array Accelerator Self-
Test Error Occurred. Array Accelerator is
disabled.
Replace the Array Accelerator or the
SMART-2DH Controller.
1799
Slot x Drive Array - Drive(s) Disabled due to
Array Accelerator Data Loss.
Select
F1
to continue with logical drives
disabled.
Select
F2
to accept data loss and to reenable
logical drives.
Data stored in the Array Accelerator has been
lost, therefore the drives have been temporarily
disabled. Press
F2
to acknowledge the data
loss and reenable the logical drives. Restore
data from backup.