Compaq ProLiant 7000 SMART-2DH Array Controller Reference Guide - Page 99

Installation of the SMART-2DH Array Controller is now complete. Reboot - service manual

Page 99 highlights

6-31 Updating the Compaq Insight Manager Agents If you are using Compaq Insight Manager, you will need to update the Insight Agents for this monitoring utility for support of the new SMART-2DH Controller. If you used SmartStart 3.40 or later to install the operating system on a new SMART-2DH Controller installation or upgrade your driver in an existing installation the agents were automatically updated for you by SmartStart, you will not have to manually update the agents. If you did not use SmartStart 3.40 or later as part of your SMART-2DH Controller installation, you must manually update the Insight Agents. The correct agents can be obtained from your local Compaq Reseller or Authorized Compaq Service Provider. Refer to the documentation included with Compaq Insight Manager for the correct procedure for updating agents. Installation of the SMART-2DH Array Controller is now complete. Reboot the server to begin using the array controller. SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: G-CH06.DOC Last Saved On: 2/27/98 12:01 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

6-31
SMART-2DH Array Controller Reference Guide
Writer: Pamela King
Project: SMART-2DH Array Controller Reference Guide
Comments: 295469-002
File Name: G-CH06.DOC
Last Saved On: 2/27/98 12:01 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Updating the Compaq Insight
Manager Agents
If you are using Compaq Insight Manager, you will need to update the Insight
Agents for this monitoring utility for support of the new SMART-2DH
Controller.
If you used SmartStart 3.40 or later to install the operating system on a new
SMART-2DH Controller installation or upgrade your driver in an existing
installation the agents were automatically updated for you by SmartStart, you
will not have to manually update the agents.
If you did not use SmartStart 3.40 or later as part of your SMART-2DH
Controller installation, you must manually update the Insight Agents. The
correct agents can be obtained from your local Compaq Reseller or
Authorized Compaq Service Provider. Refer to the documentation included
with Compaq Insight Manager for the correct procedure for updating agents.
Installation of the SMART-2DH Array Controller is now complete. Reboot
the server to begin using the array controller.