Creative AWE64 User Manual - Page 29
Input/Output I/O Addresses - midi
View all Creative AWE64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
If your card encounters a conflict with a peripheral device, you may need to change its resource settings. If you are using Windows 95, run the Device Manager. If you are using Windows 3.1x, run the configuration utility that comes with your PnP configuration manager. For details, see Appendix D, "Resolving Conflicts". When any resource setting is changed, ensure the environment variables (see "Understanding the Environment Variables" on page B-3) reflect the changes as well. You can view your system environment by typing SET at the DOS prompt. Input/Output (I/O) Addresses I/O addresses are communication areas used by your computer's central processor to distinguish among various peripheral devices connected to your system when sending or receiving data. Table B-1 lists the default I/O address ranges assigned by the PnP system to various devices on your audio card. Table B-1: Possible default I/O addresses occupied by the audio card. I/O Address Range Device 200H to 207H Game/Joystick port 220H to 22FH Audio interface 330H to 331H MPU-401 UART MIDI 388H to 38BH Stereo music synthesizer 620H to 623H, A20H to A23H, E20H to E23H Advanced WavEffects synthesizer 100H 3D Stereo Enhancement device B-2 Understanding the Installation