D-Link DFE-2616IX User Guide - Page 59

Out-of-Band Management and Console, Settings

Page 59 highlights

Out-of-Band Management and Console Settings You can use the Out-of-Band/Console Setting menu to choose whether to use the hub RS-232 serial port for console management or for out-of-band TCP/IP communication using SLIP, and to set the baud rate used for SLIP communications. The following fields can be set: ♦ System Restart Out-of-Band Baud Rate. This parameter determines the serial port baud rate that will be used the next time the hub is restarted. It applies only when the serial port is being used for out-ofband (SLIP) management; it does not apply when the port is used as a console port. Available speeds are 1200, 2400, 9600, and 19200 bits per second. ♦ Out-of-Band Dial Up Phone Number. This information is stored as a reference for the benefit of the system manager and does not cause the hub to dial out. ♦ System Restart Serial Port Setting. This parameter determines whether the serial port should be used for out-of-band (SLIP) management or for console management, starting from the next time the hub is restarted. It can be set to either onsole" or ut-of-Band." Master Hub Setup and Management 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

Master Hub Setup and Management
47
Out-of-Band Management and Console
Settings
You can use the Out-of-Band/Console Setting menu to choose whether to use
the hub
RS-232 serial port for console management or for out-of-band
TCP/IP communication using SLIP, and to set the baud rate used for SLIP
communications.
The following fields can be set:
System Restart Out-of-Band Baud Rate
.
This parameter determin-
es the serial port baud rate that will be used the next time the hub is
restarted.
It applies only when the serial port is being used for out-of-
band (SLIP) management; it does not apply when the port is used as a
console port.
Available speeds are 1200, 2400, 9600, and 19200 bits
per second.
Out-of-Band Dial Up Phone Number
.
This information is stored as
a reference for the benefit of the system manager and does not cause
the hub to dial out.
System Restart Serial Port Setting
.
This parameter determines
whether the serial port should be used for out-of-band (SLIP) man-
agement or for console management, starting from the next time the
hub is restarted.
It can be set to either
onsole” or
ut-of-Band.”